Braking Valve Adjustment
The braking valve (BV) on the hydraulic manifold con-
trols the stopping time for the cutting deck blades. The
braking valve is adjustable. If adjustment of the braking
valve is correct, the cutting deck blades should come to
a complete stop within 7 seconds after the PTO switch
is disengaged.
2
If blade stopping time is incorrect, adjustment of the
braking valve (BV) can be performed as follows:
NOTE: Do not remove the braking valve from the hy-
1
draulic manifold for adjustment.
1. Loosen lock nut on braking valve (Fig. 72).
2. To decrease blade stopping time, turn the adjust-
ment shaft on the valve in a counterclockwise direction.
Figure 72
1.
Manifold assembly
2.
Braking valve (BV)
3. To increase blade stopping time, turn the adjust-
ment shaft on the valve in a clockwise direction.
4. Tighten lock nut to secure adjustment.
5. Check blade stopping time and readjust braking
valve as needed.
Groundsmaster 3500- D
Page 4 - 57
Hydraulic System (Rev. G)