The Installation Space; Dimensions And Clearances - Monogram ZISP480DHSS Installation Instructions Manual

Table of Contents

Advertisement

Design Guide - Standard Installation

THE INSTALLATION SPACE

*Finished Width
6"
Electrical
85" max
Area
Finished
Opening
24"
5"
Water Supply
3 1/2"
*The finished cutout width must be:
35-1/2" for 36" models
41-1/2" for 42" models
47-1/2" for 48" models
Water And Electrical Locations
The opening must be prepared with the electrical and
the cold water supply located as shown.
The Cutout Depth Must Be 24"
The refrigerator will project forward, slightly beyond
adjacent cabinetry for standard installation.
Additional Specifications
• A 115 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch
circuit or circuit breaker is recommended. Install
a properly grounded 3-prong electrical receptacle
recessed into the back wall. Electrical must be located
on the rear wall as shown.
NOTE: GFI (ground fault interrupter) is not recommended.
• The water line can enter the opening through the floor
or back wall. The water line should be 1/4" O.D. copper
tubing or GE SmartConnect
water line and water connection location, long enough
to extend to the front of the refrigerator. Installation of
an easily accessible shut-off valve in the water line is
required.
36" Models 12"
42" Models 18"
48" Models 20"
5"
75" From Floor
to Bottom
of Electrical
Area
5"
3 1/2"
kit between the cold

DIMENSIONS AND CLEARANCES

35", 41", or 47"
Case Width
*83-1/2"
at
Rear
36", 42" or 48"
Frame to Frame
Depth Including Handles 26-7/8"
Product Clearances
These refrigerators are
equipped with a 3-position
door stop. The factory-set
115° door swing can be
adjusted to 130°, or to 90°
if clearance to adjacent
cabinets or walls is
restricted.
130° Door Swing
A
Models
A
36"
13"
15"
42"
13"
19"
48"
15"
20"
Allow minimum clearances for the freezer door
(Dimension A) and fresh food door (Dimension B) for a full
130° door swing and to allow for pan removal.
For a 90° door swing, allow 4" min. clearance to a wall.
If the 90° door stop position is used, pan access is
maintained, but pan removal is restricted.
See the illustrations on pages 10 and 11 to determine
door swing interaction with adjacent cabinets or
countertops.
6
25-3/8" Framed Models
* Shipping height.
The refrigerator can
be adjusted to fit
into a cutout that
is 84-1/2" in height.
*84"
Use leveling legs
From
and wheels for a
Floor
maximum 1" height
adjustment.
115° Door Swing
A
90° Door Swing
B
B
C
4"
*Min. Distance
20-5/8"
26-5/8"
28-5/8"
B
23-7/8"
Behind
Frame
C
to Wall

Advertisement

Table of Contents
loading

Table of Contents