Design Guide (For Zids240); The Installation Space; Product Clearances; Side-By-Side Installations - Monogram ZIDS240 Installation Instructions Manual

Double-drawer built-in refrigerator
Table of Contents

Advertisement

Available languages

Available languages

FOR MODEL ZIDS240 WITH STAINLESS STEEL DRAWERS AND HANDLES

THE INSTALLATION SPACE

IMPORTANT: Double-Drawer Refrigerators are
designed to be built-in only. They cannot be used
free-standing.
Locate
Outlet
8-1/2"
10-1/2"
9"
9" Max.
34-1/2"-35"
Max.
1-1/2"
1-1/2"
23-3/4" Min.
NOTE:
Handle and
handle standoff
depth is 2-1/8"
The cutout depth should be 24"
NOTE: The unit is designed to be flush with the
surrounding cabinets.
Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is
required. An individual properly grounded branch circuit
or circuit breaker is recommended. Install a properly
grounded 3-prong electrical receptacle recessed into
the back wall as shown. Electrical must be located on
rear wall as shown. NOTE: GFCI (ground fault circuit
interrupter) is not recommended.
SIDE-BY-SIDE INSTALLATIONS –
Stainless Steel Models Only
For a complete refreshment center, install a Double-
Drawer Refrigerator beside a Beverage Center, Wine
Chiller/Wine Reserve, Fresh-Food Refrigerator or Bar
Refrigerator with Icemaker.
• A side-by-side installation requires at least a 47-1/2"
wide opening. No trim kits required.
• Products must operate from separate, properly
grounded receptacles.
4
Design Guide
24"
34-1/4"
to 34-3/4"
25-7/8"
34-1/4"
Including
to 34-3/4"
Handles
23-3/4"

PRODUCT CLEARANCES

When installed in a corner:
Double-Drawer
Clearance for Door
Opening 2-1/2" min.
Allow 2-1/2" min. clearance between Double-Drawer
and adjacent cabinet, wall or other appliances. Allow
22" min. clearance from the front for drawer opening.
NOTE: Clearances are based on the noted 2-1/8"
handle standoff depth.
• Test the drawer openings. Carefully open and close
the drawers. The drawers should not rub or catch on
adjacent cabinetry. Notify the installer if the drawers
make contact with cabinetry.
Choose the location:
• These products may be closed in on the top and
three sides as long as the front is unobstructed for air
circulation and proper access to the drawers.
• Do not install these products where the temperature
will go below 55°F (13°C) or above 100°F (37°C).
• These products are not designed to be stacked one over
the other.
10-1/2"
34-1/2"-35"
15"
Countertop
22" min.
Locate
Outlet
10-1/2"
24"
14"
9"
9"
1-1/2"
47-1/2" Min.
1" = 2.5 cm; 1' = 0.3 m
31-51545-6

Advertisement

Table of Contents
loading

This manual is also suitable for:

Zidi240

Table of Contents