Logout Parameter Response - Fujitsu MAA3182FC Series Manual

Hide thumbs Also See for MAA3182FC Series:
Table of Contents

Advertisement

1.7.4.2 Logout Parameter Response pages
5
4
bit
7
6
WD Byte
1
0
Type Code
= h '00'
1
Type Code Extension
= h '00'
2
Orig Proc
Res Proc
Reserved
Assc Valid
Assc Valid
= b '0'
= b '0'
= b '00'
3
2
0
(MSB)
1
Originator Process Associator
2
3
3
0
(MSB)
1
Responder Process Associator
2
3
4
0
1
2
3
3
2
1
0
Response Code
Reserved
= h '00'
(LSB)
(LSB)
Reserved
= h '00'
Reserved
= h '00'
Reserved
= h '00'
Reserved
= h '00'
C141-E054-02EN
These pages are used by PRLO_ACC.
(1) Type Code [PL:W01/B0]
00h: The drive neither supports nor checks this
field.
The drive responds with 00h by ACC.
(2) Type Code Extension [PL:W01/B1]
00h: The drive neither supports nor checks this
field.
The drive responds with 00h by ACC.
(3) Originator
Process
[PL:W01/B2/bit 7]
0b: The drive does not support this bit and
responds with 0b by ACC.
(4) Responder
Process
[PL:W01/B2/bit6]
0b: The drive does not support this bit and
responds with 0b by ACC.
(5) Response Code [PL:W01/B2/bit3-0]
1h: Request executed.
The drive responds with 1h by ACC when
PRLO is executed.
(6) Originator Process Associator [PL:W02]
0000h: The drive does not support this field and
responds with 0000h by ACC.
(7) Responder Process Associator [PL:W03]
0000h: The drive does not support this field and
responds with 0000h by ACC.
Associator
Validity
Asscociator
Validity
1 - 47

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maf3364fc seriesMag3091fc seriesMag3182fc series