Fujitsu MAA3182FC Series Manual page 291

Hide thumbs Also See for MAA3182FC Series:
Table of Contents

Advertisement

Table 5.3
K*
C*
Q*
4
03
xx Peripheral device write fault
32
01 Defect list update failure
These are errors detected in the operation of the
disk drive.
4
15
xx Positioning error
This is an error of the disk drive's seek system.
4
32
00 No defect spare location available
No usable alternate blocks exist on the disk
drive.
4
40
nn Diagnostic failure on component 'nn'
An error was detected in the IDD's self-diagnosis.
4
44
nn Internal target failure
An internal hardware error or a microcode
detection error was detected in the IDD.
4
4C
Ax Microcode list error
The microcode, etc. recorded on the disk media
cannot be read correctly.
4
4C
Ex Calibration failed
C4
xx Drive failure
The initial seek was terminated abnormally. Or,
a serious error was detected in the drive's control
system.
5
20
00 Invalid command operation code
21
00 Logical block address out of range
24
00 Invalid field in CDB
25
00 Logical unit not supported
26
00 Invalid field in parameter list
There is an error in the command specification
contents.
6
29
xx Power on, reset, or TARGET RESET occurred
6
2A
01 Mode parameters changed
The MODE SELECT parameters were changed
by another INIT.
*
K: Sense Key
Q: Sub-sense code
5 - 14
Sense data error classification (2 of 3)
Outline of Error
C: Sense Code
L: Logging Necessary? (shown in Section 5.2.3)
C141-E054-02EN
Recovery Method
L*
(See Table 5.4.)
Need
7
Need
12
None
19
Need
13
Need
20
Need
5
Need
10
None
2
None
16
None
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maf3364fc seriesMag3091fc seriesMag3182fc series

Table of Contents