Errors On Loop (Refer To Fp-Ph, Section 29.9); Detail Errors And Action - Fujitsu MAA3182FC Series Manual

Hide thumbs Also See for MAA3182FC Series:
Table of Contents

Advertisement

1.10
Errors on Loop (Refer to FP-PH , Section 29.9)
This section describes errors which may occur on the loop and actions to be taken for them.
Table 1.16, Detail errors and action lists types of errors and actions for them by number. For
details of the actions to be taken for errors, refer to Table 1.17, Actions by recipient.
Error Category
1) Loop Failure
2) Loop Errors
3) Sequence timeout
4) Delimiter Errors
5) Address ID Errors
6) Frame_control Errors
7) Data Frame Errors
Note:
The contents of Seq. Recp. Action for each error item are described for each item number
in Table 1.17, Action by recipient.
Table 1.16 Detail errors and action
Specific Error
a) Loss of signal
b) Loss of Sync > timeout period
c) Loss of Sync
a) timeout during Sequence
b) timeout at end of Sequence
a) Class not support
b) Delimiter usage error (SOFc1 while
connected)
c) Abnormal frame termination
d) EOFa received
e) Incorrect SOF or EOF
a) incorrect D_ID
b) incorrect S_ID
a) CRC
d) TYPE not support
e) Invalid Link Control
f) Invalid R_CTL
g) Invalid F_CTL
h) Invalid OX_ID
i) Invalid RX_ID
j) Invalid SEQ_ID
k) Invalid SEQ_CNT
l) Invalid DF_CTL
m) Exchange Error
n) Protocol Error
o) Incorrect length
p) Unexpected Link_Continue
q) Unexpected Link_Response
r) Login Required
s) Excessive Sequences attempted
t) Unable to Establish Exchange
u) RO out of bounds
c) Buffer not available – Class 3
e) missing frame error detected
C141-E054-02EN
Seq Recp Action
12
12
11
9
9
2
2
1
1
1
2
2
1
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
1
13
1 - 73

Advertisement