Fujitsu MAA3182FC Series Manual page 272

Hide thumbs Also See for MAA3182FC Series:
Table of Contents

Advertisement

(2)
Mode = 0, 0, 1: Header + data, with address specification
The format of the data transferred to the INIT when this mode is specified is the same as the
format of the data in the case of Mode = 0, 0, 0, with the data stored in the IDD's data buffer
transferred to the INIT following the 4-byte header. In this mode, the address in the data
buffer can be specified in the "Buffer address" field in the CDB.
The "Transfer byte length" field in the CDB specifies the total number of bytes of header and
buffer data that can be received by the INIT. The IDD reads the data from the data buffer
beginning from the byte position in the data buffer specified in the "Buffer address" field of
the CDB and continuing in order, then adds the 4-byte header to it and transfers it to the INIT.
Data transfer is completed at the point when the number of bytes of the header and data from
the IDD's data buffer, specified in the "Transfer byte length" field, has been transferred, or at
the point when transfer of the header and all the data in the IDD's data buffer, to the final byte
position, has been completed. When zero is specified in the "Transfer byte length" field, this
command is terminated without executing a data transfer.
The format and contents of the 4-byte header transferred in this mode are the same as in the
case of Mode = 0, 0, 0. However, the "Effective buffer data length" field in the header
indicates the size (byte length) of the data from the byte position in the data buffer specified in
the "Buffer address" field in the CDB to the final byte position in the data buffer, including
that byte. Also, the length of the buffer data transferred to the INIT by this command is the
value for the number of bytes in the ["Transfer byte length" field in the CDB – 4 bytes] or the
value indicated in the "Effective buffer data length" in the header, whichever is smaller.
(3)
Mode = 0, 1, 0: Data only, with address specification
The data transferred to the INIT when this mode is specified is only the data which the IDD
reads from the data buffer. The header is not transferred as it is in Mode = 0,0,0 and Mode =
0,0,1. In this mode, address in the data buffer can be specified in the "Buffer address" field in
the CDB.
The "Transfer byte length" field in the CDB specifies the total number of bytes of buffer data
that can be received by the INIT. The IDD reads the data in order beginning from the byte
position in the data buffer specified in the "Buffer address" field and transfers it to the INIT.
Data transfer is completed at the point when the number of bytes of buffer data specified in the
"Transfer byte length" field has been completed or transfer of the buffer data to the final byte
position of the IDD's data buffer is completed. When zero is specified in the "Transfer byte
length" field, this command is terminated without executing a data transfer.
C141-E054-02EN
4 - 129

Advertisement

Table of Contents
loading

This manual is also suitable for:

Maf3364fc seriesMag3091fc seriesMag3182fc series

Table of Contents