You will need the following components to install the RPSD Lock:
RPSD Lock device
the CO line assigned as the RMATS channel (on customer premises)
the PBX modem (on customer premises)
6 position wire (length depends on local configuration)
two modular connectors
two DB25 connectors (male)
RS-232 cable
administration terminal
AC outlet
RPSD Lock power pack
Connecting the RPSD Lock to the CO Line
The following components are needed to connect the RPSD Lock device to the CO line:
RPSD Lock
the CO line assigned as the RMATS channel
two modular connectors
6 position wire
RJ11 connector (for the CO line)
To connect the RPSD Lock device to the CO line, use the following procedure:
The customer must contact the technical support center to get the port number for the
1
RMATS channel.
Locate the CO line for the RMATS port where it connects to the modem.
2
Install an RJ11 receptacle on the CO line.
3
Connect a wired modular connector to the CO line.
4
Plug the modular connector on the other end of the wire into the
5
of the RPSD Lock.
Note:
Bypass connectors are optional. See Figure 2-1.
port on the back
Telco
Hardware Installation Procedures
2-13