5800
Saks
Tr ansmitters Table
Alsod= *O APPENDIX
A toward the end of tbie xnenual
for tmmmmtt
- er input loops and button locatiom.
Model
Description
Input Type And Speoial
Notes
5801
WirelessPanic
.
Unit has4 pushbuttons, eachwitha uniqueInput (loop) code.
Transmitter
Eachpushbutton mustbe assigned to a zone.
"3"for RF (supervised), or "4"forUR (unsupervised).
No&. Input loop(button) No. 4 mustalways beueed.
5802
Pendant
"5"for BR (button typetransmitter).
5802CP
Belt clip
(Personal Emergency)
Transmitters
5802MN
Miniature Personal
"3"for RF (supemiesd), or "4"for UR (unsupervised).
Emergency Trans.
5803
Wireless Key
" Has 3 pushbuttons, eachwith a uniqueinput'(loop) c ode.
Transmitter
" Eachpushbutton mustbe assigned to a zone.
"5"for BR (button @pe transmitter).
Note:
A ll buttonsmust be assigned the sameInput Type.
Wireless
"3"for RF (supervised).
5607
Photoelectric
At the'TRANSMIT NOW" prompt, faultthedetector a sfollows:
a) On many detectors,press the specialtest switch(not test button)
provided for faulting the detector(see detector's insim.xtiona) t hen
release.
No*
With somedetectors, two contacts must be shortedto fault the
detector.Disengagedetector'scover and swing coveropen - these
contactsare on the PC board near a blue jumper (see detector's
instructions). Momentarily short these
contactswith a small
screwdriver.
A singlekeypadbeepwill occurwhenthe detector is fiwltedthe fist
time.
b) Wait
6-8
seconds, then press and release the test switch (or
momentarilyshortthe contacts) again. 2 beeps willoccur i f thecontrol
hasaccepted t heinput code, a nda summary display showing thelearned
input (loop) No.wilI appear.
5816
Door/Window
"
Haatwouniqueinput (loop)zonexonefw a wiredclosed circuit contact l oop,
Transmitter
andthe otherfor a built-in reedswitch (usedin conjunction w itha magnet).
Eitheror bothmaybe used.
"3"for RF (supervised).
5817
Multi-Point Universal
c Hasthreeuniqueinput (loop)cock onefor a DIP switch settable "Prim@'
Transmitter
contact l oop,andtheothersfortwo"Auxiliary" closed circuit contact l oops.
" The "Prim@' loopmaybe setf=
a) Repeating or Single!t'ransmissio%
b) NormallyOpenor NormallyClosed Circuit
c)Slowor FastResponse
d) 3-Minuteor No 'lknsmiasionInhibit.
DIP Switch-
Setall DIP switches t otheOFF position whenleamin g the
serialnumber.
"3"for RF (supervised).
Note:
All loops must be assigned the sameInput Type.
5818
RecessedMagnetic
'3"
forRF (supervised).
Contact 'Ikansmitter
58'49
Glassbreak
'W
for RF (supervised).
Deteetor~
utter
Pm Deteetar/
"3"
for RF (supervised).
Transmitter
The cover must be on the unit when
learning the serial
number.
earnin<
a
transmitter's ID code(s), any
PIR that maybe in thevicini~ (andis notbeinglearned) should
7 When'1
covered w itha clothj
tissue, etc., to
preventactivation ofthat PIR.
.be
40-