14, 48: Abort : Vertex command error.
(Illegal command on vertex channel)
14, 49: Internal : PCode Error, Bad Curve.
14, 50: Internal : PCode Error, DY within curve.
14, 51: Abort : Model material not loaded.
14, 52: Abort : Support material not loaded.
14, 53: Abort : Model head motor not ready.
14, 54: Abort : Support head motor not ready.
14, 55: Abort : Find home failed, X home and X eot both on
14, 56: Abort : Find home failed, Y home and Y eot both on
14, 57: Abort : Find home failed, X home timeout
14, 58: Abort : Find home failed, Y home timeout
Note: These errors occur most often due to
a problem with the motor, not the switch
14, 59: Abort : Find home failed, X home not tripped
14, 60: Abort : Find home failed, Y home not tripped
Note: These errors occur most often due to
a problem with the motor, not the switch
14, 61: Abort : Find home failed, X home tripped
14, 62: Abort : Find home failed, Y home tripped
1. If this message is displayed on LCD ONLY, replace SBC Ram.
2. If this message is not displayed on the LCD, (seen in outfile), RAM is NOT the root cause.
3. If the frequency of the error is greater than once every three months,
replace the controller board.
This error will not be displayed. Software development use only
This error will not be displayed. Software development use only
Note: System does not recognize material is loaded
1. Reload material
1. Power cycle machine - remember to move head away from switches.
2. Gen2 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP3, 7, 16 & 21.
Note: X home -J10, pin 15, Y home- J12, pin 22, X EOT - J10, pin 24, Y EOT- J12, pin 11.
Gen 3 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP12, 13, 18 & 19.
Note: X home -J10, pin 2, Y home- J12, pin 22, X EOT - J10, pin 8, Y EOT- J12, pin 11.
3. Using LED's/test points: Check to see if switch state toggles.
If not, check sensor and/or umbilical cable (for X) / mid-unit harness (for Y).
4. Using LED's/test points: Check to see if switch state toggles.
If not, check switch and/or umbilical cable (for X) / mid-unit harness (for Y).
1. Power cycle machine - remember to move head away from switches.
2. If chatter in motor, check motor and/or motor cable (for Y) / umbilical cable (for X).
3. Check for obstacles obstructing X or Y movement.
4. Using LED's/test points: Check to see home box toggles when sensor is activated.
If not, check sensor and/or umbilical cable (for X) / mid-unit harness (for Y).
1. Power cycle machine - remember to move head away from switches.
2. Using LED's/test points: Check to see home box toggles when sensor is activated.
If not, check sensor and/or Umbilical Cable (for X) / Mid-Unit Harness (for Y).
3. Gen 2 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP3, 7, 16 & 21.
Note: X home -J10, pin 15, Y home- J12, pin 22, X EOT - J10, pin 24, Y EOT- J12, pin 11.
Gen 3 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP12, 13, 18 & 19.
Note: X home -J10, pin 2, Y home- J12, pin 22, X EOT - J10, pin 8, Y EOT- J12, pin 11
1. Power cycle machine - remember to move head away from switches.
2. Using LED's/test points: Check to see home box toggles when sensor is activated.
If not, check sensor and/or umbilical cable (for X) / mid-unit harness (for Y).
3. Gen 2 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP3, 7, 16 & 21.
Note: X home -J10, pin 15, Y home- J12, pin 22, X EOT - J10, pin 24, Y EOT- J12, pin 11.
Gen 3 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP12, 13, 18 & 19.
Note: X home -J10, pin 2, Y home- J12, pin 22, X EOT - J10, pin 8, Y EOT- J12, pin 11