Dimension BST 1200 / SST 1200 Service Guide
14, 63: Abort : Find home failed, X eot tripped
14, 64: Abort : Find home failed, Y eot tripped
14, 65: Abort : Find home failed, X eot not tripped
14, 66: Abort : Find home failed, Y eot not tripped
Note: Receive interrupt but switch not tripped.
14, 67: Abort : Head temperature too high
- Liquefier is too hot, smell burning plastic (+300deg)
14, 68: Abort: Illegal PMD Command
14, 69: Abort: XY PMD Read Checksum error
14, 70: Abort: XY PMD Write Checksum error
14, 71: Abort: Z PMD Read Checksum error
14, 72: Abort: Z PMD Write Checksum error
14, 73: Abort: Head TC Board Configuration error
14, 74: Unexpected contact with unknown limit.
This message occurs when we interrupt for contact with a
limit switch, but when we read which limit we interrupted for,
there are no limit switches set. This is normally associated
with an intermittent wire in the harness to one of the limit switches.
14, 75: Unknown
14, 76: Software bug
(Internal software bug)
14, 77: Buffer is larger than the data
14, 78: Buffer is smaller than the data
(Command channel formatting issue between controller and SBC)
1. Power cycle machine - remember to move head away from switches.
2. Using LED's/test points: Check to see limit box toggles when switch is activated.
If not, check switch and/or umbilical cable (for X) / mid-unit harness (for Y).
3. Gen 2 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP3, 7, 16 & 21.
Note: X home -J10, pin 15, Y home- J12, pin 22, X EOT - J10, pin 24, Y EOT- J12, pin 11.
Gen 3 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP12, 13, 18 & 19.
Note: X home -J10, pin 2, Y home- J12, pin 22, X EOT - J10, pin 8, Y EOT- J12, pin 11
1. Power cycle machine - remember to move head away from switches.
2. Using LED's/test points: Check to see limit box toggles when switch is activated.
3. Gen 2 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP3, 7, 16 & 21.
Note: X home -J10, pin 15, Y home- J12, pin 22, X EOT - J10, pin 24, Y EOT- J12, pin 11.
Gen 3 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP12, 13, 18 & 19.
Note: X home -J10, pin 2, Y home- J12, pin 22, X EOT - J10, pin 8, Y EOT- J12, pin 11
1. T/C is bad reporting below set point temperature..
2. Head Board is bad
3. Head T/C cables are not plugged in.
4. Replace the umbilical cable.
1. If error occurs more than once a month replace the controller board
1. If error occurs more than once a month replace the controller board
1. If error occurs more than once a month replace the controller board
1. If error occurs more than once a month replace the controller board
1. If error occurs more than once a month replace the controller board
Not used on 1200 systems
1. Power cycle machine - remember to move head away from switches.
2. Using LED's/test points: Check to see limit box toggles when switch is activated.
If not, check switch and/or umbilical cable (for X) / mid-unit harness (for Y).
3. Gen 2 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP3, 7, 16 & 21.
Note: X home -J10, pin 15, Y home- J12, pin 22, X EOT - J10, pin 24, Y EOT- J12, pin 11.
Gen 3 - Check for loose pins on J10 & J12 on the PDB. Check signals at TP12, 13, 18 & 19
No error code associated with an error
Cycle power.
1. Cycle power.
2. Replace single board computer.
Page 8-9