8. TROUBLESHOOTING OF THE
COMMUNICATIONS ERRORS
If a communications error occurs, the facsimile equipment
(1) Gives the alarm (intermittent bleep) for approximately four seconds.
(2) Indicates the appropriate error message on the LCD.
(3) Prints the transmission report during fax transmission.
■ Definition of error codes on the communications list
Calling
(1)
Code 1
10
11
11
11
11
11
11
11
17
* Available set Germany in EEPROM Customizing (Function Code 74) only.
Code 2
08
Wrong number called.
01
No dial tone detected before start of dialing.
02
Busy tone detected before dialing.
03
2nd dial tone not detected.
05
No loop current detected. *
06
Busy tone detected after dialing or called.
07
No response from the remote station in sending.
10
Unobtainable tone detected after dialing.
07
No response from the calling station in receiving.
3-65