<WSW04> (Transfer facility setting)
Selector No.
Earth function in transfer facility
1
(Not used.)
2
Dual tone detection frequency in
ICM recording (Not used.)
3
Dual tone detection sensitivity in
4
ICM recording (Not used.)
Length of time added to time
designated by selectors 3 and 4
5
on the WSW 24 (time between
CML ON and pseudo ring
backtone return).
6
Break time length for flash
I
function
8
Note:
• Selectors 1 and 5 through 8 are not applicable in those countries where no transfer
facility is supported.
• Selectors 6 and 8: Break time length for flash function
These selectors set the break time length. This setting is effective only when the flash
function is selected for the [Search/Speed Dial] button by using the function switch.
Function
No. 6 7 8
App. 1-9
Setting and Specifications
0: Not added 1: +4 seconds added
0 0 0: 80 ms
0 0 1: 100 ms
0 1 0: 110 ms
0 1 1: 120 ms
1 0 0: 200 ms
1 0 1: 250 ms
1 1 0: 500 ms
1 1 1: 700 ms