9.28 Register Solenoid ASSY

(1) Remove the bind B M3x10 Taptite screw.
(2) Remove the Register solenoid ASSY and the Solenoid release spring.
Register solenoid lever

9.29 Ejector Solenoid ASSY

(1) Remove the bind B M3x10 Taptite screw.
(2) Remove the Ejector solenoid and the Solenoid release spring.
Frame L
Solenoid release spring
Fig. 5-151
Solenoid release spring
Fig. 5-152
5-122
Taptite, bind B M3x10
Register solenoid ASSY
Frame L
Taptite, bind B M3x10
Ejector solenoid
Ejector solenoid lever