White Balance Adjustment (Pd-156 Board) - Sony DCR-TRV140 Service Manual

Hide thumbs Also See for DCR-TRV140:
Table of Contents

Advertisement

6. White Balance Adjustment (PD-156 board)

Correct the white balance.
If deviated, the LCD screen color cannot be reproduced.
Mode
CAMERA
Subject
Arbitrary
Measurement Point
Check on LCD display
Measuring Instrument
Adjustment Page
D
Adjustment Address
A8, A9
The LCD screen should not be
Specified Value
colored.
Note 1: Check the white balance only when replacing the fol-
lowing parts. If necessary, adjust them.
1. LCD panel
2. Light induction plate
3. IC5501
Adjusting method:
Order Page Address Data
1
0
01
01
A8
80
2
D
A9
80
3
A8
4
D
A9
5
0
01
00
Note 2: To write in the non-volatile memory (EEPROM), press
the PAUSE button each time to set the data.
Procedure
Press PAUSE button.
(Initial value)
Check that the LCD screen is
not colored. If not colored,
proceed to step 5.
Change the data so that the
LCD screen is not colored.
(Note 2)
DCR-TRV140/TRV140E/TRV140M
5-29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trv140eTrv140m

Table of Contents