Others - Kubota BX1860 Workshop Manual

Hide thumbs Also See for BX1860:
Table of Contents

Advertisement

BX1860, BX2360, BX2660, RCK48(P)-18BX, RCK54(P)-23BX, RCK60B-23BX, LA203, LA243, WSM

[13] OTHERS

Bleeding Fuel System
Air must removed:
1. When the fuel filter (2) or lines are removed.
2. When tank is completely empty.
3. After the tractor has not been used for a long period of time.
Bleeding procedure is as follows:
1. Fill the fuel tank with fuel.
2. Turn the key switch to "ON" position for about 30 seconds.
Doing so allows fuel pump (1) to work and pump air out of the fuel
system.
3. Start the engine and run for about 30 seconds, and then stop the
engine.
(1) Fuel Pump
Replacing Fuse
1. The tractor electrical system is protected from potential damage
by fuses.
A blown fuse indicates that there is an overload or short
somewhere in the electrical system.
2. If any of the fuses should blow, replace with a new one of the
same capacity.
IMPORTANT
• Before replacing a blown fuse, determine why the fuse blew
and make any necessary repairs.
procedure may result in serious damage to the tractor
electrical system.
If any of the fuses should blow, replace with a new one of the
same capacity.
Protected Circuit
[Fuse Box]
Fuse No.
Capacity (A)
(1)
15
(2)
15
(3)
15
(4)
20
(5)
10
(6)
10
Fuse No.
Capacity (A)
Slow Blow Fuse
(7)
(50A)
(B) Fuse Box
G-30
G GENERAL
(2) Fuel Filter
W1021149
Failure to follow this
Protected circuit
Solenoid
Hazard
ACC
Working Light
DC Outlet
Timer Relay
Protected circuit
Check circuit against wrong battery
connection
W1023430
KiSC issued 06, 2009 A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents