9.
Power consumption of the hydraulic propeller governor:
max. ............................................ 600 W
10.
Power consumption of the vacuum pump:
max. ............................................ 300 W
11.
Power consumption of the external alternator:
max. ............................................ 1200 W
12.
Deviation from bank angle
max. ............................................ 40°
13.
Rotation reverse the direction of engine rotation
max. ............................................ 1 rotation
Effectivity: 912 UL /A / F
OM Rev. 1
NOTE:
Up to this value the dry sump lubrication
system warrants lubrication in every flight
situation.