Draining Transmission Fluid/Coolant - Kubota RTV 900 Workshop Manual

Hide thumbs Also See for RTV 900:
Table of Contents

Advertisement

RTV900, WSM
2. DISASSEMBLING AND ASSEMBLING
[1] DISMOUNTING TRANSAXLE
Draining the Transmission Fluid
1. Place oil pans underneath the transmission case.
2. Remove the drain plug (1).
3. Drain the transmission fluid.
4. Reinstall the drain plug (1).
(When refilling)
• Fill up from filling port after removing the filling plug (2) until
reaching the upper notch on the dipstick (3).
• After running the engine for few minutes, stop it and check the oil
level again, add the fluid to prescribed level if it is not correct
level.
Transmission fluid capacity
IMPORTANT
• Use only KUBOTA SUPER UDT fluid. Use of other oils may
damage the transmission.
Refer to "LUBRICANTS, FUEL AND COOLANT". (See page
G-1.)
• Do not mix different brands of fluid together.
(1) Drain Plug with Magnet
(2) Filling Plug
(3) Dipstick
Draining Coolant
CAUTION
• Never open the radiator cap while operating or immediately
after stopping. Otherwise, hot water will spout out from the
radiator. Wait for more than ten minutes to cool the radiator,
before opening the cap.
1. Stop the engine and let cool down.
2. Remove the protective cover (4).
3. Remove the radiator coolant drain plug (3) to drain the coolant.
4. Remove the radiator cap (1) to completely drain the coolant.
5. After all coolant is drained, close the drain plugs.
Radiator with
Coolant capacity
recovery tank
(1) Radiator Cap
(2) Recovery Tank
9-S2
NEW TRANSMISSION
10 L
2.6 U.S.gals
2.2 Imp.gals
A : Oil level is acceptable within this
range.
W1013492
4.0 L
4.2 U.S.qts.
3.5 Imp.qts.
(3) Radiator Coolant Drain Plug
(4) Protective Cover
W1013915
KiSC issued 04, 2006 A