Setting The Room Temperature Set Point In Comfort Mode; Setting The Domestic Hot Water Temperature - DeDietrich AWHP 4MR–EMC 24/28 MI HYBRIDE User Manual

Alezio g hybrid
Table of Contents

Advertisement

Fig.40
Accessing the heating parameters
Fig.41
Confirming the heating circuit
MW-3000249-3
Fig.42
Displaying the User menu
7611444 - v02 - 11122015

6.2.3 Setting the room temperature set point in comfort mode

Note
The room temperature set point can be managed via the TIME
PROG sub-menu dedicated to timer programming.
Note
1. Access the heating shut-down pressing the
MW-5000144-2
2. Display the parameters for the desired circuit by pressing the
The name of the circuit and the heating water temperature set point
are displayed alternately.
3. Access setting of the heating water temperature set point by press­
ing the
4. Set the heating water temperature set point by pressing
5. Confirm the new temperature set point by pressing the
Note
Press the
Note
The setting of the room temperature set point in comfort mode can
also be accessed in the User menu, parameter CP072.

6.2.4 Setting the domestic hot water temperature

The domestic hot water is produced by the boiler instantaneously.
1. Access the User menu.
2. Select the parameter HP097 by pressing the
through the list of adjustable parameters. Confirm by pressing the
3. Change the value by pressing the
the
4. Go back to the main display by pressing
MW-5000040-4
To set the room temperature set point, it is necessary to set
CP071 parameter available in the User menu.
When the setting is made in a reduced mode range, this setting
short cut is used only to set the temperature set point in the
comfort mode corresponding to CP072.
key. Confirm by pressing the
key.
key to cancel all input.

key.
key.
6 Settings
key twice.
key.
or
key.
or
keys to scroll
or
keys. Confirm by pressing
.

or
key.