6 Settings

6
Settings
6.1

List of parameters

Tab.20 List of parameters
Parameters
Description
AM010
Pump speed
AM012
Status
AM014
Sub-Status
AM019
Water pressure
AM027
Outside temperature
AM056
Flow rate in the system
AM091
Active season
0 = Winter frost protection
1 = Winter
2 = Summer deadband
3 = Summer
AM101
Set point calculated
CM030
Room temperature measured
CM040
Circuit start temperature
CM060
Pump speed
CM070
Calculated circuit temperature
CM120
Circuit operating mode
0 = Auto
1 = Manual
2 = Frost protection
3 = Temporary
CM130
Current active mode
0 = Frost protection
1 = Reduced
2 = Comfort
3 = Anti-legionella
CM190
Desired room temperature set point
DM001
Domestic hot water tank temperature - bottom position
32

6.1.1 Menu List

Information menu

User menu
Installer menu
Manual Forcing menu
Failure menu
Sub-menu COUNTERS
Sub-menu TIME PROG
Sub-menu CLOCK
Sub-menu PROG COOL
6.1.2 Information menu
Certain parameters are displayed:
according to certain system configurations,
according to the options, circuits or sensors actually connected.
Unit
PCB
EHC-02
%
x
x
x
bar
x
°C
x
l/min
x
°C
x
°C
x
°C
%
°C
°C
x
°C
x
7611444 - v02 - 11122015
PCB
SBC-04
x
x
x
x
x
x
x
x
x
x
x