Advertisement

5. Operating the appliance
User level - #MEASURES Menu
Parameter
Description
DT INSTALLATION Installation temperature delta
Total electrical energy consumed
(1)
ELEC.ENERGY
Total electrical energy consumed in the previous year
ELEC.ENERG.Y1
(1)
Total electrical energy consumed two years ago
ELEC.ENERG.Y2
(1)
Total thermal energy yield
THERM.ENERGY
(1)
Total thermal energy yield in the previous year
THERM.ENERG.Y1
(1)
Total thermal energy yield two years ago
THERM.ENERG.Y2
(1)
(1) The parameter is only displayed for the options, circuits or sensors actually connected.
5.3

Changing the settings

C Menu
Parameter
DAY TEMP.A
NIGHT TEMP.A
(1) (2)
ROOMTEM.COOL A
(2)
DAY TEMP.B
(2)
NIGHT TEMP.B
(2) (1)
ROOMTEM.COOL B
(2)
DAY TEMP.C
(2)
NIGHT TEMP.C
(2) (1)
ROOMTEM.COOL C
(2)
DHW TEMP.
(1) The parameter is only displayed if the corresponding circuit can handle cooling.
(2) The parameter is only displayed for the options, circuits or sensors actually connected.
25
5.3.1.
To set the various heating, DHW and swimming pool temperatures,
proceed as follows:
1. Press the C key.
2. To select the desired parameter, turn the rotary button.
3. To modify the parameter, press the rotary button.
4. To modify the parameter, turn the rotary button.
5. To confirm, press the rotary button.
MODE
C002266-A
Adjustment range Description
5 to 30 °C
Desired room temperature in comfort periods on circuit A
5 to 30 °C
Desired room temperature in reduced periods on circuit A
22 to 30 °C
Desired room temperature set point in cooling mode
5 to 30 °C
Desired room temperature in comfort periods on circuit B
5 to 30 °C
Desired room temperature in reduced periods on circuit B
22 to 30 °C
Desired room temperature set point in cooling mode
5 to 30 °C
Desired room temperature in comfort periods on circuit C
5 to 30 °C
Desired room temperature in reduced periods on circuit C
22 to 30 °C
Desired room temperature set point in cooling mode
10 to 65 °C
Desired domestic hot water temperature in the DHW circuit 55 °C

Setting the set point temperatures

To go back to the previous display, press the key j .
To cancel, press key h .
AWHP-2 MIT-IN-2 iSystem
Unit
K
kWh
kWh
kWh
kWh
kWh
kWh
Factory setting
20 °C
16 °C
25 °C
20 °C
16 °C
25 °C
20 °C
16 °C
25 °C
10/06/2015 - 7616372-001-05