will show "XXXX" in the user code field. To deactivate the keypad lock,
repeat the operation described above.
Note: the keypad will remain locked even if the switchboard station is
turned off and back on.

CALL REROUTING

Using adapter circuit 1038/70 and a telephone interface or PABX, the
calls received by the switchboard station can be rerouted to a standard
or cordless telephone. For adapter circuit installation, see the section
covering installation.
A function key must be programmed to activate and deactivate the call
rerouting feature.
Example: If key F2 was programmed for the call rerouting function
(function 4), the display will show the following message when the key
is pressed:
23/05/2000
0001
From this time onwards, the attendant can leave the switchboard
station and receive calls made to it from apartment stations or entrance
panels directly on his cordless phone. If a call is received from a
main entrance panel, the attendant can also open the door by dialing
R35 (systems equipped with PABX) or R5 (systems equipped with
telephone interface).
Upon returning to the switchboard station, the attendant must press
key F2 again to disable the call rerouting function.

OTHER DISPLAY MESSAGES

• Call to a nonexistent apartment station: the display will show:
23/05/2000
0001
• Call cannot be made because it would interrupt another call before
the end of the programmed engaged time: the display will show:
23/05/2000
0001
This message will remain until the programmed engaged time for
the call in question has ended.
This message will also appear if a call between two switchboard
stations cannot be made.
• Data line not connected or short circuited:
ERROR
DATA LiNE
23/05/2000
0001
2
−−−− sec.5a
GUARD DOOR SWITCHBOARD STATION Ref. 038/40
SPECIAL FUNCTIONS
>TEL
08:10:00
ERR7
08:10:00
BSY
08:10:00
08:10:00
• The message will remain on the display for as long as the problem
persists.

USING A PRINTER

The switchboard station is provided with an RS232-C serial port for
connection to a printer (see the section headed 'Installation').
The following types of message can be printed once the print function
has been configured and the printer has been correctly connected to
the switchboard station. All messages will be provided with a date/time
stamp:
• Configuration report: This report is printed at the end of switchboard
station configuration, and indicates all settings established for the
station.
• Door lock release messages: Printed when a door lock is
released.
• Attendant messages: Printed following operations carried out by
the switchboard attendant.
Messages are listed below together with examples.
Door lock release messages:
• Door opened by entering door lock release code at entrance
module.
• Door opened by command from switchboard station.
• Door opened by command from apartment station.
• Door opened by pressing lobby pushbutton.
• Door opened through postal lock release.
• Door opened by Magikey.
• Door opened through proximity sensor.
Examples:
Door at secondary entrance panel 12 from apartment station 1001:
23/05/2000 08:10:00
SECONDARY 12
[LKRL]
iND.SET 1001
Door at main entrance panel 001 opened from switchboard station
0001:
23/05/2000 08:10:00
MAiN 001 [LKRL]
0001
Door at main entrance panel 10A opened by entering door lock release
code 12432389:
23/05/2000 08:10:00
MAiN 10A [LKRL]
LKRL CODE 12432389
Attendant messages:
• Switchboard station ON/OFF.
• Switchboard station changed to DAY service.
• Switchboard station changed to NIGHT service; zones transferred.
• Call made from switchboard station to apartment station.
• Call made from apartment station to switchboard station.
• Panic alarm call made from apartment station to switchboard
station
• Call/panic alarm call from apartment station queued.
• Call deleted from queue by attendant using dedicated key.
• Call deleted automatically from queue: attendant called back or
another switchboard station deleted call.
Example:
Switchboard station in Night service with zones transferred to
switchboard station 0013:
23/05/2000 08:10:00
SWBD —> 0013
[NiGHT]
Call from switchboard station to apartment station 1000:
23/05/2000 08:10:00
SWBD —> 1000
[CALL]
Call from apartment station 1000 to switchboard station:
23/05/2000 08:10:00
1000 —> SWBD
[CALL]
Panic alarm call from apartment station 1000 to switchboard station:
23/05/2000 08:10:00
1000 —> SWBD
[MEMOR]
DIGIVOICE - Technical Manual