SPECIFICATIONS

Space requirements:
Dimensions (mm):

ELECTRICAL PROPERTIES

Power supply voltage range (+V; 0V):
Power supply voltage range (+F; 0F):
Max. current draw (+V; 0V):
Consumption in load units (LU):
Drive signal outputs:
Maximum applicable voltage:
Maximum current draw rating:
Output resistance (typical):
Service temperature range:
DIGIVOICE - Technical Manual
GUARD DOOR SWITCHBOARD STATION Ref. 038/40
SPECIFICATIONS - DESCRIPTION OF COMPONENTS
54
260 x 220 x 70
6 to 25.2vdc
30 to 36vdc
450mA
30vdc
00Ohm
- 5°C to 45°C

DESCRIPTION OF COMPONENTS

GRAPHIC DISPLAY
The guard door switchboard station is provided with a backlit graphic
display featuring five lines with 10/20 characters each.
During active service, characters shown on the display are divided into
zones as follows:
dd/mm/yyyy HH:MM:ss
CCCC > T-ppp nn*rrrr!
The first and second lines are identical: the first indicates the status
of voice line 1, while the second indicates the status of voice line 2 as
explained below.
Zone
(1 character)
This zone shows the character
managed by the switchboard station.
eee
Zone
(3 characters)
This zone shows the code of the main entrance panel currently in
communication with the switchboard station or waiting to be connected
to it.
40LU
iiii
Zone
(4 characters)
This zone shows the code of the apartment station called by the main
entrance module, or the code of the apartment station called by the
0mA
switchboard station.
f
Zone
(1 character)
This zone shows a symbol indicating the type of voice connection. This
symbol may be:
when main entrance panel
and the switchboard station has intercepted the call but has not yet
answered it;
when the switchboard station is in communication with the main
entrance panel identified by code
when the switchboard station is in communication with the apartment
station identified by code
when main entrance panel
iiii
station
.
Zone
(1 character)
This zone may contain the symbol
iiii
station
intercepted by the switchboard station has not yet been
called by the attendant. If the switchboard attendant presses the call
button, apartment station
disappears from the display.
IIII
Zone
(4 characters)
This zone shows the code for an apartment station that has called the
switchboard station. If the switchboard attendant does not take the
call, the display field is cleared and the call is stored in memory.
!
Zone
(1 character)
This zone may contain the symbol
IIII
station
has made a panic alarm call to the switchboard station.
eeefiiii
eeefiiii
iiii! dddd
on the display line currently being
...
eee
has called apartment station
eee
;
iiii
, and;
eee
is in communication with apartment
, which indicates that apartment
iiii
will be called and the symbol
!
, which indicates that apartment
iiii
3
sec.5a −−−−

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1038/401138/311138/31138/41138/61138/7

Table of Contents