Installation-Terminal Designations - urmet domus 1138/18 Manual

Hide thumbs Also See for 1138/18:
Table of Contents

Advertisement

INSTALLATION-TERMINAL DESIGNATIONS

The switchboard station is designed for either tabletop or wall
mounting.
In tabletop installations, the switchboard station can be combined with
video module Scaitel.
Electrical connections are made via a 19-pole junction box with the
following terminals:
+V
Logic power supply positive input
0V
Logic power supply negative input
D
Data line
FA1
Outward voice conductor, channel 1
FB1
Return voice conductor, channel 1
FA2
Outward voice conductor, channel 2
FB2
Return voice conductor, channel 2
+F
Voice power supply positive input
0F
Voice power supply negative input
CV
Drive output, video module wall bracket
SCM
Drive output, video entrance panel relay – motor riser cable
SCT
Drive output, video entrance panel relay – camera riser cable
SL
Drive output, video entrance panel relay - local
S12
Drive output, video entrance panel relay - lines 1/2
S1
Drive output, video entrance panel relay - line 1
S2
Drive output, video entrance panel relay - line 2
RPCH Drive output, supplementary call tone ringer
RPAL Drive output, supplementary alarm ringer
0V
Logic power supply negative input
TABLETOP MOUNTING
The switchboard station leaves the factory ready for tabletop
installation. Tabletop mounting support (8) ensures that it is positioned
at the correct angle.
video module 732/ installation
The video module can be installed to the right or the left of the
switchboard station using bracket 1732/92. Two brackets and four
screws to be installed in the associated seats (9) are supplied for
combining switchboard station with the video module. Support (48)
and the two self-adhesive feet (49) supplied together with the unit must
be applied to the video module bracket.
WALL MOUNTING
The switchboard station leaves the factory ready for tabletop
mounting.
If it is to be installed on the wall, proceed as follows:
1) Remove the tabletop mounting support (7) and the two selfadhesive
feet (13).
2) Using a small screwdriver, release the catch (12) retaining
switchboard station body (1) to base plate.
3) Take switchboard station body (1) off base plate (14).
4) Open the handset cradle section (6) and unscrew the handset
base.
5) Secure the base to the wall using the four wall plugs supplied
together with the unit, inserting them through holes (8).
PC vERSION INSTALLATION
The switchboard station can be controlled from a PC. In this case,
the PC's keyboard and mouse are used instead of the switchboard
station keypad, and the switchboard station displays are shown on
the PC monitor in a WINDOWS 3.11, 95 or 98 window. To configure
the switchboard station for this type of operation, turn off switchboard
station power supply and proceed as follows:
1) Using a small screwdriver, release the catch (12) retaining
switchboard station body (1) to base plate.
2) Take switchboard station body (1) off base plate (14).
3) Cut jumper connection (54) using wire cutters.
4) Connect the switchboard station serial port (16) to one of the PC's
serial ports (COM1 through COM4) using a twisted pair (55).
4
−−−− sec.5a
GUARD DOOR SWITCHBOARD STATION Ref. 038/40
INSTALLATION-TERMINAL DESIGNATIONS
5) Reassemble switchboard station and supply it with power.
The switchboard station can now be controlled only by the PC,
using the PCVOICE program.
The PCVOICE can be downloaded free of charge from the Urmet
Domus Internet site at http://www.urmetdomus.com.
Minimum system requirements for the PC include a 486 processor or
higher, 800 x 600 or 1024 x 768 pixel graphic resolution, and Windows
3.11, 95 or 98 operating system.
SWITCHBOARD STATION SERIAL
CONNECTION (RS232) WITH P.C. AT MAX 3 m
5
9
4
8
3
7
2
6
1
9-WAY FEMALE
SWITCHBOARD STATION SERIAL
CONNECTION (RS232) WITH P.C. XT MAX 3 m
5
5
9
9
4
4
8
8
3
3
7
7
2
2
6
6
1
1
9-WAY FEMALE
Note: PC connecting cable must be less than 3 meters long.
PRINTER INSTALLATION
If connected to a printer, the switchboard station can print certain types
of system information (see the paragraph headed 'Using a Printer).
The Ref. 1033/72 printer is recommended. Printer cable must be
connected to switchboard station serial port (16).
Communication parameters are as follows:
Programmable speed: 4800, 9600, 19200 bit/s
Data format: 1 start bit, 8 data bits, no parity bit, 1 stop bit , XON-XOFF
protocol.
Twisted pairs must not be used in connecting cable (56).
SWITCHBOARD STATION SERIAL
CONNECTION. (RS232) WITH PRINTER MAX. 3 m
5
9
4
8
3
7
2
6
1
9-WAY FEMALE
Note: printer connecting cable must be less than 3 meters long.
5
9
4
8
3
P.C.
7
AT
2
6
1
9-WAY FEMALE
55
13
25
12
24
11
23
10
22
9
21
8
20
7
P.C.
19
XT
6
18
5
17
4
16
3
15
2
14
1
25-WAY FEMALE
5
9
4
8
3
PRINTER
7
2
56
6
1
9-WAY MALE
DIGIVOICE - Technical Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

1038/401138/311138/31138/41138/61138/7

Table of Contents