PROGRAMMABLE PARAMETERS
The following parameters must be programmed for each doorphone
with single-port decoder:
• Riser cable code.
• User code.
• Codes for additional keys.
The riser cable code identifies the riser cable on which the doorphone
with single-port decoder is physically installed. The riser cable code
can assume values between "01" and "JJ", and must necessarily
be the same as the riser cable code assigned to the corresponding
secondary entrance panel.
If the doorphone is installed between a main entrance panel and a
secondary entrance panel, the assigned riser cable code must be "X1"
if the doorphone is connected to voice line 1, and "X2" if the doorphone
is connected to voice line 2.
For systems with no secondary entrance panels, the riser cable code
"01" must be assigned to all doorphones with single-port decoder.
The user code is a unique 4-character alphanumeric code which
positively identifies each user. Codes between '0001' and 'JJJJ' can
be assigned. Each user code must be unique in the system.
The two additional keys on the doorphone can be assigned codes in
order to program them for special functions as follows:
Programmed code
0000
0980 ÷ 0989
and
0990 ÷ 0998
0999
1000 ÷ JJJJ
PROGRAMMING WITH TERMINAL 038/56
See the instruction manual provided with the terminal.
PROGRAMMING WITH A CALLING DEvICE
The doorphone with single-port decoder is provided with a key which
activates the code programming cycle, and a LED which provides
programming feedback and indicates any data line problems.
Programming codes are sent to the doorphone by means of a calling
device (i.e., an entrance module or switchboard station).
The calling device must be connected to the doorphone with singleport
decoder via the data bus.
The LED will flash each time a code is programmed.
At the end of the programming cycle, wait 2 seconds for the doorphone
to enter normal operating status.
To access the riser cable code and user code programming procedure
(basic programming), briefly press the programming key. When the
programming LED goes on, the riser cable code and user code can be
transmitted from a calling device. The programming cycle ends when
the user code is received, and the LED will go off.
To access the additional key code programming procedure (extended
programming), hold down the programming key for approximately 3
seconds until the programming LED begins to flash. When the key is
released, the LED will remain on and codes for additional keys T1 and
T2 can be transmitted from a calling device. The programming cycle
ends when the last code is received, and the LED will go off.
Programming conditions and the corresponding LED states are shown
in the table below:
If it is not necessary to program all codes, press the programming key
to exit from the procedure after entering the last desired code.
NOTICE: To ensure that system maintenance can be efficiently
performed, it is essential that programming data be recorded on the
label provided on doorphone top casing interior.
DIGIVOICE - Technical Manual
DOORPHONE WITH SINGLE-PORT DECODER Ref. 38/3
Function
Call guard door switchboard station.
Self-activation on the main entrance
panel
with
corresponding
(maximum of 19 main entrance panels).
Self-activation on secondary entrance
panel connected to the same riser cable.
Call special doorphone.

INSTALLATION

Condition
Programming key pressed briefly
(riser cable code and user code
programming).
Calling device transmits riser
cable code
Calling device transmits user
code.
Programming key pressed for
approximately 3 seconds (key
T1 code and key T2 code
programming).
Calling device transmits code for
key T1.
Calling device transmits code for
key T2.
No data line or data line short
circuited.
NOTE: • When programming with a calling device, the "0" preceding
each code must be omitted.
• To assign the riser cable code "X1" or "X2" when
programming from an entrance module, press the "Key" at
the same time as key "1" or "2": the display will show "-1"
code
or "-2". Press the call button to confirm.
• To assign the riser cable code "X1" or "X2" when
programming from a guard door switchboard station, press
key "1" or "2" and then confirm by pressing the shift key and
the call button simultaneously.
• If an additional key is to be programmed to call the
switchboard ("0000" ), simply press the call button without
entering a code.
INSTALLATION
The doorphone base is provided with holes for retention to wall using
the 6 mm diameter wall plugs supplied together with the unit.
DIAGNOSTICS
When the system is supplied with power and the doorphone with
single-port decoder is not being programmed, the LED will signal
malfunctions as follows.
Continuous flashing: data bus short circuit or no data bus.
LED status
On.
Indicates that device is ready to
be programmed.
Flashes and then stays on.
Indicates that riser cable code
has been programmed.
Flashes and goes off.
Indicates that user code has been
programmed.
Flashes and stays on when key is
released.
Indicates that device is ready to
be programmed
Flashes and then stays on.
Indicates that code for key T1 has
been programmed.
Flashes and goes off.
Indicates that code for key T1 has
been programmed.
Flashes.
sec.5a −−−−