PROGRAMMING TERMINAL 038/56 CONNECTION
The switchboard station is provided with a connector (17) for
programming terminal 1038/56. The terminal can be used for centralized
programming of all entrance modules installed in the system.
Note: connector (17) is used to program entrance modules, and NOT
to program the switchboard station.

CONFIGURATION

To operate correctly, the switchboard station must be appropriately
configured at the time of installation. Configuration programming
consists of assigning parameters to all operating variables.
The following message will appear on the display the first time the
switchboard station is turned on:
REL1.0
TO CONFiG
----------
This message indicates that the switchboard station must be
configured.
To configure the switchboard station, first press the
the display. Then activate the configuration cycle, noting the following
points:
• Parameters must be entered only by means of the keypad (37).
• After selecting each parameter (with the exception of language in
Step 0), press the call button
• The system will check all entered data, rejecting any data which are
not congruent.
• Any errors made in entering parameters can be corrected with the
delete key
before confirming entries.
• To return to the beginning of the programming procedure at any
time, press scroll key
.
M
To activate the configuration cycle, supply power to the switchboard
station, hold down the
SHIFT
in succession as needed to bring the language configuration step to
the display.
STEP 0 - LANGUAGE
The following menu will appear on the switchboard station display:
LANGUAGE
----------
1=iTAL
3=ENGL 4=DEUT 5=ESPA
The following languages can also be programmed:
Press the number key associated with the desired language.
Setting
6
7
8
9
10
11
DIGIVOICE - Technical Manual
GUARD DOOR SWITCHBOARD STATION Ref. 038/40
button to clear
to confirm selection.
key, and press key
as many times
1
2=FRANC
Language
Hebrew
Russian
Dutch
Turk
Portuguese
Polish
CONFIGURATION
STEP  - SWITCHBOARD STATION CODE
The display will show:
To change switchboard station code, simply enter the new code with
the keypad and press the call button
The switchboard station code must be unique in the system: the same
code must not be assigned to two switchboard stations, nor must the
same code be assigned to a switchboard station and a main entrance
panel.
The switchboard station code must not belong to a zone assigned to
other switchboard stations in the system.
The switchboard station code is also used to route calls from a main
entrance panel to the individual switchboard station.
STEP 2 - ENGAGED TIME
The display will show:
BUSY TiME
(10,20,30,40 S.)
To change the engaged time, simply select the desired time using the
appropriate number key (1 through 4) and press the call button
The engaged time must match that programmed for the entrance
modules.
STEP 3 - RING DURATION
The display will show:
CALL TiME
(1,2,3,4,5 S.)
To change ring duration, simply select the desired time using the
appropriate number key (1 through 5) and press the call button
Programmed ring duration establishes the length of time that
the apartment station doorphones will ring when called from the
switchboard station.
STEP 4 - NUMBER OF vOICE LINES
The display will show:
NUMBER SPEECH LiNES
(1,2)
STEP 1
----------
0001
CODE
(MAX 4 CHARACTERS)
.
STEP 2
----------
20
STEP 3
----------
3
STEP 4
----------
1
.
.
5
sec.5a −−−−