Cable Gland Fitting Instructions
To enable correct assembly of the cable gland the 'O'-ring (Fig. 13 item 1) must be
placed over the cable before the clamping insert (Fig. 13 item 2) can be tightened.
Note: Cable diameter range:- 6.5 mm to 9.5 mm.
Supply Cord Extension
The pumps are fitted with a supply cord to the following specification:-
All models . . . . . . . . . . . . . . . . . .HO5VV-F3 G 0.75 mm² - 6 Amp rated cable.
If the supply cord is to be extended, a cord of the same specification should be used.
Any connections or junction boxes used should be specifically suited for the application
and installed in accordance with the manufacturers instructions.
STEP 6 COMMISSIONING
WARNINGS:
The motor casing can become hot under normal operating conditions,
care should be taken to ensure it cannot be touched during operation.
Do not run pump without guards and terminal box lid correctly fitted.
The pump chamber must be full of water at all times. Seal damage will
result if the pump runs dry.
1. System Flushing
This pump incorporates push-in connectors and plastic components that
must not come into contact with solder flux, acid-based descalents or
aggressive cleaning agents. The pipework system should be flushed out
prior to the pump being connected to ensure any contaminants/chemical
residues and foreign bodies are removed from elsewhere in the system.
2. Water Supply
Always ensure that water storage capacity is adequate to meet the demand.
Ensure the pump chamber is full of water before starting the pump. Failure
to do this could result in seal damage. To ensure dry running does not
occur the pump must be primed as described in priming section. Do not
run pump dry.
1
2
Fig. 13
- 13 -