Technical Specification - Stuart Turner Monsoon U1.5 bar Twin Installation Instructions Manual

Monsoon universal twin pump
Table of Contents

Advertisement

TECHNICAL SPECIFICATION

Model
Power supply
Volts/phase frequency
Motor enclosure
Type of motor
Max. power consumption
Full load current
Rating
Max. no. starts per hour
Max inlet head
Max head (closed valve)
Max working pressure*
Max ambient air temperature
Pressure vessel air pre-charge
Max water temperature**
Min water temperature
Length
Width
Height (excluding flexible hoses)
Gross weight (packed)
Stuart Turner reserve the right to amend the specification in line with its policy of
continuous development of its products.
Note:
For information on other voltages/frequencies which are not shown, consult any
supplementary instruction sheet supplied, or the rating label attached to the
pump.
*Note: Max working pressure is the maximum pressure that can be applied to the
pump internal casing under any installation conditions.
**Note: In normal circumstances the temperature of stored water should never exceed
65°C. A stored water temperature of 60°C is considered sufficient to meet all
normal requirements and will minimize deposition of scale in hard water areas.
Maximum permissible water temperature 65°C.
U1.5 bar
U2.0 bar
Twin
Twin
230/1/50
230/1/50
IPX4
IPX4
Induction
Induction
355 Watts
435 Watts
1.5 Amps
1.9 Amps
Continuous
Continuous
(S1) @ 9 l/min
(S1) @ 9 l/min
& above
& above
(Both ends
(Both ends
pumping)
pumping)
60
60
8 metres
8 metres
15 metres
20 metres
600 kPa
600 kPa
(6.0 bar)
(6.0 bar)
40°C
40°C
90 kPa (0.9
90 kPa (0.9
bar) (13 psi)
bar) (13 psi)
65°C
65°C
4°C
4°C
265 mm
265 mm
162 mm
162 mm
243 mm
243 mm
9.2 Kg
9.2 Kg
- 18 -
U3.0 bar
U4.0 bar
Twin
Twin
230/1/50
230/1/50
IPX4
IPX4
Induction
Induction
655 Watts
875 Watts
2.9 Amps
3.9 Amps
Continuous
Continuous
(S1) @ 9 l/min
(S1) @ 9 l/min
& above
& above
(Both ends
(Both ends
pumping)
pumping)
60
60
8 metres
12 metres
30 metres
40 metres
600 kPa
600 kPa
(6.0 bar)
(6.0 bar)
40°C
40°C
90 kPa (0.9
130 kPa (1.3
bar) (13 psi)
bar) (18.5 psi)
65°C
65°C
4°C
4°C
265 mm
300 mm
162 mm
162 mm
243 mm
243 mm
10.4 Kg
12.5 Kg
U4.5 bar
Twin
230/1/50
IPX4
Induction
1135 Watts
5.1 Amps
Continuous
(S1) @ 9 l/min
& above
(Both ends
pumping)
60
12 metres
45 metres
600 kPa
(6.0 bar)
40°C
130 kPa (1.3
bar) (18.5 psi)
65°C
4°C
310 mm
162 mm
243 mm
13.3 Kg

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents