B. Clearances to Combustibles (UL and ULC)
BACKWALL / SIDEWALL
A
B
C
D
CORNER INSTALLATION
E
F
E
F
Figure 3.3
INSTALLATION: Full Vertical
Single Wall Pipe
Double Wall Pipe
INSTALLATION: Horizontal
with 2 foot minimum vertical
Off Appliance Top
Single Wall Pipe
Double Wall Pipe
INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Double Wall air
insulated connector pipe with UL 103 HT** Listed factory-built Class "A" chimney, or
a masonry chimney. (Manufactured home must be equipped with a spark arrestor).
Maximum depth of Alcove shall be no more than 48 inches (1219mm) with a minimum
height of 84.0 (2134mm) from floor to bottom of ceiling and the reference clearances.
**In Canada must comply with Standard CAN/ULC-S629-M87 for the 650°C Fac-
tory-built chimney.
8
Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15
NOTE: Clearances may only be reduced by means
approved by the regulatory authority having jurisdiction
90° OFF TOP
UP & OUT CEILING
CLEARANCE
STOVE TO CEILING
CLEARANCE
A
B
C
17.5
11.5 32.5
15.5
9.5
29.5
17.5
11.5 32.5
15.5
9.5
29.5
WARNING
Fire Risk.
Comply with all minimum clearance to combusti-
bles as specified.
Failure to comply may cause house fire.
H
G
D
E
F
20
8
22.5
16
4
18.5
20
8
22.5
16
4
18.5
ALCOVE SIDE VIEW
G
A
B
ALCOVE TOP VIEW
J
I
G
H
I
42
NA
NA
NA
42
NA
NA
NA
42
18
NA
NA
42
13
18
31.5
J