INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Model(s):
Adventure-III
EPA CERTIFIED WOODBURNING
APPLIANCE
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfire and generate
poisonous gases (i.e. carbon monoxide).
Installation and service of this appliance should be
performed by qualified personnel. Hearth & Home
Technologies recommends HHT Factory Trained or
NFI Certified professionals.
1
Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15
Installation Manual
Installation & Appliance Set-Up
NOTICE: DO NOT DISCARD THIS MANUAL
WARNING
If the information in these instruc-
tions is not followed exactly, a
fire could result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other flamma-
ble vapors and liquids in the vicinity of this or
any other appliance.
• Do not overfire - If appliance or chimney con-
nector glows, you are overfiring. Overfiring
will void your warranty.
• Comply with all minimum clearances to com-
bustibles as specified. Failure to comply may
cause house fire.
WARNING
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
appliance.
Alert children and adults to hazards of high temperatures
High temperatures may ignite clothing or other
flammable materials.
Keep clothing, furniture, draperies and other flammable
materials away.
To obtain a French translation of this manual, please contact
your dealer or visit www.quadrafire.com
Pour obtenir une traduction française de ce manuel, s'il vous
plaît contacter votre revendeur ou visitez www.quadrafire.com
HOT SURFACES!
Glass and other surfaces are hot
during operation AND cool down.
NOTE

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire Adventure-III

  • Page 1 Keep clothing, furniture, draperies and other flammable Fire Risk. materials away. For use with solid wood fuel only. Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide). NOTE Installation and service of this appliance should be To obtain a French translation of this manual, please contact performed by qualified personnel. Hearth & Home your dealer or visit www.quadrafire.com Technologies recommends HHT Factory Trained or NFI Certified professionals. Pour obtenir une traduction française de ce manuel, s’il vous plaît contacter votre revendeur ou visitez www.quadrafire.com Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 2: Table Of Contents

    F. Install Checklist ..............6 Dimensions and Clearances .....7 Mobile Home Installation ....22 A. Appliance Dimensions ............7 Accessory List .........23 B. Clearances to Combustibles ..........8 C. Hearth Protection Requirements........9 D. Locating Your Appliance & Chimney.........10 E. Chimney Termination Requirements .........10 F. 2-10-3 Rule ...............11 Quadra-Fire is a registered trademark of Hearth & Home Technologies. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 3: Important Safety Information

    This appliance is approved for mobile home installations terials: when not installed in a sleeping room and when an outside - Wood - Compressed Paper -Plywood/OSB combustion air inlet is provided. The structural integrity of - Plant Fibers - Plastic -Sheet Rock (drywall) the mobile home floor, ceiling, and walls must be maintained. Any material that can ignite and burn: flame proofed or not, The appliance must be properly grounded to the frame of the plastered or un-plastered. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 4: Getting Started

    ANCE. - Duct leaks • DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. NOTICE: HEARTH & HOME TECHNOLOGIES ASSUMES NO RESPONSIBILITY FOR THE IMPROPER PERFORMANCE May allow flue gases to enter the house. OF THE APPLIANCE SYSTEM CAUSED BY: • Inadequate draft due to environmental conditions • Downdrafts • Tight sealing construction of the structure • Mechanical exhausting devices • Overdrafting caused by excessive chimney heights • Ideal performance is with height of chimney between 14-16 feet (4.26-4.88m) measured from the base of the appliance. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 5: Negative Pressure

    D. Tools And Supplies Needed Before beginning the installation be sure the following tools and building supplies are available: Reciprocating saw Framing material Utility knife High temp caulking material Hammer Gloves Phillips screwdriver Framing square Roof sealant Drill and bits Plumb line Safety glasses Level Tape measure Misc. screws and nails Tin snips Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 6: Install Checklist

    Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed: Comments communicated to party responsible (Builder/Gen. Contractor) (Installer) (Date) Part # 4083-982• Rev A• 03/11/15 Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 7: Dimensions And Clearances

    Figure 3.1 Front View 31-1/2 in. (800mm) 27-3/4 in. (705mm) 6-1/4 in. (159mm) 3 in. (76mm) 3-3/8 in. (86mm) 26-5/8 in. (676mm) Figure 3.2 Side View (shown with optional fan) Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 8: Clearances To Combustibles

    INSTALLATION: ALCOVE Six inch (6”) (152mm) diameter listed Double Wall air insulated connector pipe with UL 103 HT** Listed factory-built Class “A” chimney, or a masonry chimney. (Manufactured home must be equipped with a spark arrestor). Maximum depth of Alcove shall be no more than 48 inches (1219mm) with a minimum height of 84.0 (2134mm) from floor to bottom of ceiling and the reference clearances. **In Canada must comply with Standard CAN/ULC-S629-M87 for the 650°C Fac- tory-built chimney. WARNING Fire Risk. • Comply with all minimum clearance to combusti- bles as specified. • Failure to comply may cause house fire. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 9: Hearth Protection Requirements

    • Illustrations/diagrams are not drawn to scale. • Actual installation may vary due to individual design preference • Hearth & Home Technologies reserves the right to alter its products. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 10: Locating Your Appliance & Chimney

    • • Frequently open doors Must have an approved and Listed cap • Must not be located where it will become plugged by • Central heat outlets or returns snow or other material • Must terminate at least 3 feet (91cm) above the roof and at least 2 feet (61cm) above any portion of the roof within 10 feet (305cm). • Must be located away from trees or other structures NOTICE: • Chimney performance may vary. • Trees, buildings, roof lines and wind conditions affect performance. • Chimney height may need adjustment if smoking or overdraft occurs. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 11: 2-10-3 Rule

    10 ft. (305cm) or more Less than 10 ft. (305cm) Wall or Parapet 2 ft. (61cm) Minimum 3 ft. (91cm) Minimum 3 ft. (91cm) Minimum Flat Roof Figure 3.7 Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 12: Chimney Systems

    Instructions: RY-BUILT CHIMNEYS. 1. Open inside wall at proper height for the chimney con- nector to entry the masonry chimney. Figure 4.1 2. Entry hole to masonry chimney must be lined with an 8 inch (203mm) minimum diameter clay liner, or equiva- lent, secured with refractory mortar. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 13: Chimney Systems

    Factory-built chimney connector (vented) Improper installation, adjustment, alteration, service or • A Listed connector (vented) must be used when installing maintenance can cause injury or property damage. Refer to this appliance in a mobile home. the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified • The Listed connectors must conform to each other to installer, service agency or your dealer. ensure a proper fit and seal. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 14: Factory-Built Chimney

    Figure 4.5 - Factory-Built Exterior Chimney UL103 HT. WARNING WARNING Fire Risk. Asphyxiation Risk. Follow Chimney Connector Manufacturer’s Instructions • DO NOT CONNECT THIS APPLIANCE TO A for Proper Installation. ONLY use connector within the CHIMNEY FLUE SERVICING ANOTHER APPLI- room, between appliance and ceiling or wall. ANCE. Connector shall NOT pass through: • DO NOT CONNECT TO ANY AIR DISTRIBUTION • Attic or roof space • Closet or similar concealed space DUCT OR SYSTEM. • Floor or ceiling May allow flue gases to enter the house. Maintain minimum clearances to combustibles Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 15: Masonry Chimney

    Fire Risk. Follow Chimney Connector Manufacturer’s When lining air-cooled factory-built chimneys:. Instructions for Proper Installation. • Run chimney liner approved to UL 1777 Type HT requirements (2100 degrees F) ONLY use connector: • Re-install original factory built chimney cap ONLY • Within the room, between appliance and ceiling or wall. • DO NOT block cooling air openings in chimney Connector shall NOT pass through: • Attic or roof space • Blocking cooling air will overheat the chimney • Closet or similar concealed space • Floor or ceiling Maintain minimum clearances to combustibles Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 16: Masonry Chimney Liner

    NOTICE: In Canada when using a factory-built chim- ney it must be safety listed, Type UL103 HT (2100oF) [1149oC] CLASS “A” or conforming to CAN/ULC- S629M, STANDARD FOR 650oC FACTORY-BUILT CHIMNEYS. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 17: Securing Chimney Components

    Failure to keep insulation or other material away from vent pipe may cause fire. WARNING Fire Risk. This appliance relies upon natural draft to operate properly. • Chimney heights exceeding 25 feet (7.62m) from base of appliance may create an over-draft situation. • Overdraft condition may create over-firing. Over-firing may ignite creosote and/or damage appliance and chimney Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 18: Appliance Set-Up

    CAUTION! DO NOT OVERTIGHTEN LOCKNUT. Square Key DOOR HANDLE NEEDS TO MOVE SMOOTHLY. Locknut 5. Install fiber handle using a clockwise motion until the fiber handle is snug against the door handle shaft. Latch Cam Figure 5.2 Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 19: Thermostat Installation

    Figure 5.5 Discard if optional fan installed Fan (optional) Thermostat Terminal Block Fan Connection Pedestal Screen (remove for optional Outside Air Kit) Power Cord Connection Figure 5.3 Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 20: Fan (Optional)

    Fan Speed Control face plate. Place the locknut on the speed control and tighten. 14. Run the wires through the channel and connect to the corresponding pin locations on control board on the left side. Figure 5.8 Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 21: Outside Air Kit Installation

    3. Attach the flex adapter to the plate with the screws pro- vided. 4. Cut a 4 1/4 inch hole in the outside wall or floor to accom- modate the outside air duct. Use 4 inch duct to directly connect the appliance to the inlet air hood supplied. Seal between the wall and duct with silicone to prevent mois- ture and cold air infiltration. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 22: Mobile Home Installation

    NOTE: Top sections of chimney must be removable to allow maximum clearance of 13.5 feet (411cm) from ground level for transportation purposes. WARNING 10. Burn wood only. Other types of fuels may generate Asphyxiation Risk. poisonous gases (e.g., carbon monoxide). NEVER INSTALL IN A SLEEPING ROOM. 11. If appliance burns poorly while an exhaust blower is on Consumes oxygen in the room. in home, (i.e., range hood), increase combustion air. 12. Installation shall be in accordance with the Manufacturers Home & Safety Standard (HUD) CFR 3280, Part 24. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 23: Accessory List

    Accessory List Doors DR-57BK-FH Black Arched Door DR-57NL-FH Black Arched Door with Satin Nickel Trim Door Upgrade Kit UK-DRNL - Door upgrade kit - Satin Nickel Fan Kit BK-350 Outside Air Kit OAK-ADV Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...
  • Page 24: Contact Information

    We recommend that you record the following pertinent information for your heating appliance. Date purchased/installed: Serial Number: Location on appliance: Dealership purchased from: Dealer phone: Notes: This product may be covered by one or more of the following patents: (United States) 5341794, 5263471, 6688302, 7216645, 7047962 or other U.S. and foreign patents pending. Quadra-Fire • Adventure-III Installation Manual • 4083-901 • Rev B • 05/15...