Advertisement

Models:
QV-Pier
QV-ST
Series: HV-IPI
Important operating
and maintenance
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fire
or explosion may result causing prop-
erty damage, personal injury, or death.
• Do not store or use gasoline or other flam-
mable vapors and liquids in the vicinity of this
or any other appliance.

• What to do if you smell gas

- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fire department.
• Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.
Quadra-Fire, a brand of Hearth & Home Technologies Inc.
1445 North Highway, Colville, WA 99114
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356,
5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481,
6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441,
6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign
patents pending.
CAUTION
DO NOT DISCARD THIS MANUAL
Read, understand and follow
these instructions for safe
installation and operation.
Printed in U.S.A.
Copyright 2006
Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06
Owner's Manual
Leave this manual with
party responsible for
use and operation.
WARNING: IMPROPER INSTALLATION,
ADJUSTMENT, ALTERATION, SERVICE OR
MAINTENANCE CAN CAUSE INJURY OR
PROPERTY DAMAGE. REFER TO THIS
MANUAL. FOR ASSISTANCE OR ADDITION-
AL INFORMATION CONSULT A QUALIFIED
INSTALLER, SERVICE AGENCY, OR THE
GAS SUPPLIER.
This appliance may be installed in an aftermarket,
permanently located, manufactured (mobile) home,
where not prohibited by local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not
convertible for use with other gases, unless a certi-
fied kit is used.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fitter;
• a CO detector shall be installed in the room where the
appliance is installed.
Please contact your Quadra-Fire dealer with any questions
or concerns.
For the number of your nearest Quadra-Fire dealer,
please call 1-800-926-4356.
Installation and Operation
1

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire HV-IPI QV-PIER

  • Page 1: What To Do If You Smell Gas

    6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064, 6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408, 2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 2: Safety And Warning Information

    DO NOT place furniture or any other combustible Young children should be CAREFULLY SUPERVISED household objects within 36 inches of the fireplace when they are in the same room as the appliance. front. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 3: Table Of Contents

    Step 12. Lighting the Fireplace ..............37 After the Installation ..................37 Maintaining and Servicing Your Fireplace ........ 38 Troubleshooting ................. 39 Warranty ..................41 = Contains updated information. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 4: Service Parts List

    QV-Pier-HV-IPI Service Parts List Beginning Manufacturing Date: 6-03 (NG, LP) Exploded Parts Diagram Ending Manufacturing Date: ______ Log Assembly Part number list on following page. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 5 593-594A ACCESSORIES Fan Kit GFK-160A Remote Control Kit RC-SMART-HNG Remote Control Kit SMART-STAT-HNG Remote Control - Multi-functional RCT-MLT-HNG Wall Switch, Multi-functional WSK-MLT Plug Adapator Kit (for WSK-MLT PLUG-ADP Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 6 QV-ST-HV-IPI Service Parts (NG, LP) Exploded Parts Diagram Beginning Manufacturing Date: 6-03 Ending Manufacturing Date: ______ Log Assembly Part number list on following page. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 7 593-594A ACCESSORIES Fan Kit GFK-160A Remote Control Kit RC-SMART-HNG Remote Control Kit SMART-STAT-HNG Remote Control - Multi-functional RCT-MLT-HNG Wall Switch, Multi-functional WSK-MLT Plug Adapator Kit (for WSK-ML PLUG-ADP Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 8: Service Parts

    Regulator, LP LPK-DXV Pilot Tube 446-301 Orifice Spud NG 446-505 Orifice Spud LP 446-517 NOTE: Replacement bulbs to be supplied by homeowner. Recommended replacements: Sylvania Mini Candelabra 75 watts. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 9: Approvals And Codes

    (in the United States), or to the CSA C22.1 Canadian Electric Code (in Canada). These models may be installed in a bedroom or bed-sitting room in the U.S.A. and Canada. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 10: Getting Started

    Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 11 (114mm) (121mm) TOP VENT COLLARS TOP STANDOFFS REAR VENT COLLARS SIDE GLASS DOOR GAS CONTROLS & LABELS GAS LINE ACCESS ELECTRICAL ACCESS Figure 1. Diagram of the QV-PIER-HV-IPI Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 12 Dimensions of the QV-ST-HV-IPI TOP VENT COLLARS TOP STANDOFFS REAR VENT COLLARS GAS CONTROLS SIDE GLASS & LABELS DOOR GAS LINE ACCESS Figure 3. Diagram of the QV-ST-HV-IPI ELECTRICAL ACCESS Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 13: Installing The Fireplace

    The minimum clearance to a perpendicular wall extending past the face of the fireplace is one inch (25 mm). The metal ends of the fireplace may NOT be recessed into combustible construction. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 14: Step 2. Framing The Fireplace

    Bottom ......1/2 ....13 Sides ......... 1 ....25 For minimum clearances, see the direct vent termination clearance diagrams on pages 25 and 26 in this manual. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 15 2 X 4 lumber or heavier. QV-PIER-HV-IPI QV-ST-HV-IPI Model QV-PIER-HV-IPI 42-1/8 42-1/2 35-3/4 QV-ST-HV-IPI 47-5/8 42-1/2 35-3/4 NOTE: DIMENSIONS SHOWN IN INCHES Figure 5. Framing Dimensions Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 16 1-1/4 TYP DVP48 8-9/16 1/2 TYP 12-9/16 NOTE: PIPES OVERLAP 1-1/4 INCHES AT EACH JOINT. Figure 6. DVP-Series Direct Vent Component Specifications (5-inch inner pipe / 8-inch outer pipe) Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 17: Step 3. Installing The Vent System

    WALL FIRESTOP PIPE LENGTH Termination kits 90 DEGREE ELBOW CEILING FIRESTOP DVP-TB1 DVP-TVHW DVK-01D DVK-TVCD PVK-80 DVP-TRAP (IPI models only) Figure 7. Vent System Components and Termination Kits Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 18 24" (610 mm) Figure 9 2. Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks Figure 12. (see Figure 10). Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 19 18’ MAX. (5.5m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + H = 50’ MAX. (15.2m) V + H = 50’ MAX. (15.2m) Figure 14. Venting with One 90° Elbow Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 20 5’ MIN. (1.5m) 10' MAX. (3.0m) 6’ MIN. (1.83m) 12' MAX. (3.6m) V + V + H = 50’ MAX. (15.2m) Figure 15. Venting with Two 90° Elbows Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 21 V + H + H = 50’ MAX. (15.2m) H + H = 18’ MAX. (5.5m) H + H = 12’ MAX. (3.6m) Figure 17. Venting with Two 90° Elbows Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 22 + H + H = 50’ MAX. (15.2m) H + H = 18’ MAX. (5.5m) H + H = 12’ MAX. (3.6m) Figure 18. Venting with three 90° elbows Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 23 6’ MIN. (1.83m) 12' MAX. (3.6m) + H + H = 50’ MAX. (15.2m) V+ V H + H = 12’ MAX. (3.6m) Figure 19. Venting with three 90° elbows Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 24: Installing Vent Components

    If the installation is for a termination cap attached directly to the fireplace, skip to the sections, Install Firestops and Vent Termination. ELBOW ELBOW SEAM FRONT VIEW Figure 21 TOP VIEW Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 25 • Cut an 10-inch X 10-inch (254mm x 254mm) hole through the ceiling, using the centerpoint previously marked. • Frame the hole with framing lumber the same size as the ceiling joists. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 26: Vent Termination

    NOTE: Keep insulation away from the vent pipe at least 1 inch (25mm). NAILS (4 REQUIRED) 7 1/4" (184mm) Figure 28. Trapezoid Termination Cap RAFTER CEILING CEILING FIRESTOP Figure 27. Attic Firestop Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 27 Figure 29. Vent Termination Minimum Clearances CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 28 12/12 to 14/12 over 14/12 to 16/12 over 16/12 to 18/12 over 18/12 to 20/12 over 20/12 to 21/12 Figure 30. Minimum Height from Roof to Lowest Discharge Opening Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 29: Step 4. Positioning, Leveling, And Securing The Fireplace

    • Secure the fireplace to the framing by nailing or screwing. • Holes are provided in the base pan for securing the unit to the floor. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 30: Step 6. The Gas Supply Line

    • At the gas line access hole the gap between the supply piping and gas access hole can be plugged with non- combustible insulation to prevent cold air infiltration. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 31: Step 8. Wiring The Fireplace

    This appliance requires that 110-120 VAC be wired to the stored, disconnect red and black wire leads to extend bat- junction box. Maintain correct polarity when wiring the junc- tery life. tion box. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 32 This will provide the shown. This will provide the best air flow (see Figure 36). best air flow (see Figure 37). Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 33: Step 9. Finishing

    19” 18” 17” 16” 15” 14” 13” 12” HOOD NOTE: 12” mantel at 23” above hood. Minimum Vertical and Maximum Horizontal Figure 39. Dimensions of Combustibles above Fireplace Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 34: Step 10. Installing Trim, Logs & Ember Material

    Glass meeting this requirement is available from the factory. Please con- tact your dealer or distributor to order. BEND TAB UNDER GRATE BAR Figure 43. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 35 The lava rock should cover the remaining base pan area (see Figure 49). Do not put lava rock on top of the glass (teco-sil). Figure 46. Figure 49. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 36: Placing The Ember Material

    Make sure to paint the glass from both sides (see Figure 51). Figure 53. Placement of the Ember Material Figure 51. The ember bed is now complete (see Figure 52). Figure 52. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 37: Ember Light Replacement

    MANUAL FOR ALL CAUTIONS, SAFETY, AND WARNING INFORMATION PERTAINING TO THE LIGHTING AND OPERATION OF THE FIREPLACE. After the Installation Figure 56 LEAVE THIS INSTALLATION MANUAL WITH THE APPLIANCE FOR FUTURE REFERENCE. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 38: Maintaining And Servicing Your Fireplace

    Task: Make a visual check of your fireplace’s flame patterns. Make sure the flames are steady - not lifting or floating. See Figure 57. The flame sensor (IPI) should be covered with flame. See Figure 32. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 39: Troubleshooting

    A wrong orifice or too high an inlet pressure can cause pilot flame to lift. The sensor rod may be contaminated. Clean sensor rod with emery cloth. Continued... Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 40 Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in. too large. c. Module is not Verify module is securely grounded to metal chassis of appliance. grounded. Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...
  • Page 41: Warranty

    This limited Lifetime Warranty is effective on all appliances sold after May 1, 2002 and supersedes any and all warranties currently in existence. 250-8620J 12/05 Quadra-Fire • QV-PIER, QV-ST Series: HV-IPI • 2005-901 Rev. G • 2/06...

This manual is also suitable for:

Hv-ipi qv-stIllage qv-pier hv-ipiIllage qv-st hv-ipi

Table of Contents