Clearances To Combustibles - Quadra-Fire 31-I ACC Installation Manual

Wood insert automatic combustion control (acc)
Hide thumbs Also See for 31-I ACC:
Table of Contents

Advertisement

31-I ACC
B. Clearances to Combustibles
32-1/4
819mm
USA 16-3/4
24-3/4 (629mm)
Without Mantel Defl ector
51 7/16
1306mm
See next page for thermal protection
In Canada a full length 6 inch (152mm) S635 fl ue liner required as per ULC S628.
In USA a minimum 5 ft length (1.82m), 6 inch (152mm) diameter fl ue liner is required as per UL 1482.
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause house fi re.
8
TOP TRIM
27-1/4
692mm
HEARTH
CANADA
EXTENSION
12in max
MANTEL
USA 23-1/2
CANADA 25-1/2 (648mm)
HEARTH EXTENSION
calculations
United States and Canada (UL and ULC)
40-11/16
1033mm
With Mantel Defl ector
41 7/16
1052mm
NOTE: Clearances may only be reduced by
means approved by the regulatory authority
having jurisdiction
7044-225D
THERMAL
PROTECTION
Floor height 0" to 6-1/2"
1-1/2 inch (38) of
(6mm to 165mm) below
insert base
Floor height greater
1 inch (25) of k =
than 6-1/2" (165mm)
below insert base
12in max
MANTEL
USA 23-1/2
CANADA 25-1/2 (648mm)
Optional
Mantel
Deflector
HEARTH EXTENSION
See next page for thermal protection
calculations
USA
& CANADA
k=3.06
0.49, R = 2.04
August 3, 2015