Parts Requiring Periodical Replacement; Operating Environment; Installation Temperature / Humidity; Installation Altitude - Minolta Magicolor 3100 Series Service Manual

Minolta laser printer service manual
Hide thumbs Also See for Magicolor 3100 Series:
Table of Contents

Advertisement

N Magenta toner cartridge:equivalent to about 6,000 prints
N Cyan toner cartridge:equivalent to about 6,000 prints
N Fuser unit:equivalent to about 100,000 prints

5.3 Parts Requiring Periodical Replacement

Following parts are replaced when a certain number of sheets are printed (life over) to prevent troubles.
N FUSE ASSY:Equivalent to about 100.000 prints
N RETARD ROLL:Equivalent to about 100,000 prints

6. Operating Environment

6.1 Installation Temperature / Humidity

Operated at: 5 to 32°C(41 to 90°F) / 15 to 85% RH

6.2 Installation Altitude

0 to 3,100m(10,170ft)

6.3 Installation Horizontality

Before and after the installation surface:within 5mm in 646mm
Right and left of installation surface:within 10mm in 560mm

6.4 Ambient Lighting

3000 Lux or less (without no direct sun beams)

7. Safety / Environment Conditions

7.1 Safety Standard

N 100V / 120V system
UL1950 3rd Edition
CSA C22.2 No.950-M95
N 220V / 240V system
IEC60950 2nd Edition

7.2 Laser Safety Standard

N 100V / 120V system
FDA21CFR Chapter 1, Subchapter J, Section 1010, 1040
N 220V / 240V system
IEC60825 Class 1 Laser Product

7.3 EMI

N 100V system
8-414

Advertisement

Table of Contents
loading

Table of Contents