Rrp10.9 S-Hvps (Pl10.1.17) - Minolta Magicolor 3100 Series Service Manual

Minolta laser printer service manual
Hide thumbs Also See for Magicolor 3100 Series:
Table of Contents

Advertisement

RRP10.9 S-HVPS (PL10.1.17)

Removal
1)
Remove the FUSER ASSY. (RRP8.1)
2)
Remove the BTR UNIT ASSY. (RRP8.4)
3)
Remove the COVER TOP MAIN. (RRP1.4)
4)
Remove the COVER ASSY FRONT HEAD. (RRP1.2)
5)
Remove the COVER MSI. (RRP1.11)
6)
Remove the TRAY ASSY MSI. (RRP1.12)
7)
Remove the COVER ASSY FRONT. (RRP1.13)
8)
Remove the COVER ASSY FRONT IN. (RRP1.10)
9)
Remove the COVER SIDE L. (RRP1.14)
10) Remove the connector (P/J5011) on the S-HVPS (PL10.1.17) from the left side surface of the printer.
11) Remove the connector (P/J5030) on the S-HVPS.
12) Remove the connector (P/J5020) on the S-HVPS.
13) Remove 4 screws securing the S-HVPS.
14) Remove the S-HVPS from the printer.
Replacement
Replace the components in the reverse order of removal.
3-244
Figure: S-HVPS Removal