RRP10.2 HOLDER TCRU ASSY (1) (PL10.1.1)

Removal
1)
Remove the FUSER ASSY. (RRP8.1)
2)
Remove the BTR UNIT ASSY. (RRP8.5)
3)
Remove the COVER TOP MAIN. (RRP1.4)
4)
Remove the COVER ASSY FRONT HEAD. (RRP1.2)
5)
Remove the COVER MSI. (RRP1.11)
6)
Remove the TRAY ASSY MSI. (RRP1.12)
7)
Remove the COVER ASSY FRONT. (RRP1.13)
8)
Remove the COVER ASSY FRONT IN. (RRP1.10)
9)
Remove the COVER SIDE L. (RRP1.14)
10) Remove the COVER SIDE R. (RRP1.9)
11) Remove the HOLDER TCRU ASSY UNIT. (RRP10.1)
12) From the HOLDER TCRU ASSY UNIT, release the hook securing the toner discharging unit of the
HOLDER TCRU ASSY (1) on the PLATE ASSY DISPENSER L (PL10.1.9) with a mini screwdriver.
13) From the PLATE ASSY DISPENSER, pull out the toner discharging unit on the HOLDER TCRU ASSY
(1) rightward.
14) Extract the connector (P/J511) of the motor from the right side surface of the HOLDER TCRU ASSY
(1).
15) Extract the connector (P/J441) and connector (P/J431) from the HOLDER TCRU ASSY (1).
16) Shift the harness from the hook at the bottom portion of the HOLDER TCRU ASSY (1).
17) Release the hook securing the HOLDER TCRU ASSY (1) to the PLATE ASSY DISPENSER.
18) Slide the HOLDER TCRU ASSY (1) rightward from the HOLDER TCRU ASSY UNIT and remove the
HOLDER TCRU ASSY (1).
Replacement
Replace the components in the reverse order of removal.
Execute the following diagnosis after having exchanged HOLDER TCRU ASSY (1).