RRP11.3 ACTUATOR I/R (PL11.1.8)

Removal
1)
Remove the COVER TOP MAIN. (RRP1.4)
2)
Remove the COVER ASSY FRONT HEAD. (RRP1.2)
3)
Remove the COVER MSI. (RRP1.11)
4)
Remove the TRAY ASSY MSI. (RRP1.12)
5)
Remove the COVER ASSY FRONT. (RRP1.13)
6)
Remove the COVER ASSY FRONT IN. (RRP1.10)
7)
Remove the COVER SIDE L. (RRP1.14)
8)
Remove the COVER SIDE R. (RRP1.9)
9)
Remove the COVER ASSY TOP PHD. (RRP1.5)
10) Remove the LINK:R. (RRP1.8)
11) Remove the MAIN DRIVE ASSY. (RRP11.5)
12) Remove the DEVE DRIVE ASSY. (RRP11.4)
13) From the right side surface of the printer, release the hook of the SPRING I/R (PL11.1.9) hitched over
the convex portion of the PLATE ASSY LEVER R (PL11.1.7).
14) From the printer, release the hook at 1 position securing the ACTUATOR I/R to the shaft on the PLATE
ASSY LEVER R.
15) Remove the ACTUATOR I/R from the PLATE ASSY LEVER R together with the SPRING I/R.
16) Remove the SPRING I/R from the ACTUATOR I/R.
Replacement
Replace the components in the reverse order of removal.