Power  on  the  VersaLASER.    Load  some  scrap 
material  of  the  same  type  you  intend  to  process 
and  set  focus  using  the  Focus  Tool.    Adjust  the 
angle  of  the  nozzle  by  loosening  the  thumbscrew 
(1),  rotating  the  bracket,  and  re‐tightening  the 
thumbscrew.  You can also adjust the height (2) by 
loosening  the  mounting  thumbscrew,  making  the 
adjustment  and  re‐tightening  the  thumbscrew.  
Use  the  Red  Dot  pointer  as  your  guide  to  where 
the laser beam will strike the material. 
 
WARNING:  Since  the  AABS    hangs  downwards 
toward  the  surface  of  your  material  and  the 
surface  of  the  table,  ensure  that  the  motion  of 
the  Focus  Carriage  will  not  cause  the  AABS    to 
mechanically  interfere  with  your  material  or 
components of the VersaLASER otherwise serious 
 
damage may occur. 
 
 
 
Usage 
If  this  is  the  first  time  using  the  AABS,  open  the  needle  valve  all  the  way,  counter  clockwise.  This  will 
result in maximum airflow.  To lock the adjustment in place, rotate the round locking nut clockwise until 
it seats. 
 
Load  and  run  a  job.    Make  sure  that  the  CCCAU  unit  turns  on  (if  purchased)  or  your  compressed  air 
source is operating when the job starts processing.  Observe how the smoke is being pushed away.  If 
you  would  like  to  reduce  the  flow  or  to  change  the  angle  or  height  of  the  airflow,  pause  the  job  and 
adjust as necessary. 
 
 
Removal 