ULS VersaLaser VL-200 Safety & Installation Instructions page 72

Table of Contents

Advertisement

Installation 
Lower the table down far enough so that you can 
attach  the  cone.  Power  off  the  VersaLASER.    By 
hand, move the X‐axis arm and Focus Carriage to a 
comfortable working position in the field. Remove 
(if present) the plug (1) with a screwdriver. 
 
Loosen  the  thumbscrew  (1)  on  the  side  of  the 
Focus  Carriage  (if  already  attached).    Insert  the 
cone (2) by pushing it straight up into the bottom 
of the Focus Carriage ensuring that it is up all the 
way and is seated properly, and gently tighten the 
thumbscrew.    If  this  is  the  first  time  using  the 
cone,  open  the  needle  valve  (3)  all  the  way, 
counter  clockwise.  This  will  result  in  maximum 
airflow through the cone.  To lock the adjustment 
in place, rotate the round locking nut (4) clockwise 
until it seats. 
 
 
 
Usage 
Power on the VersaLASER and run a job.  Make sure that the CCCAU unit turns on (if purchased) or your 
compressed air source is operating when the job starts processing.  Observe how the smoke is pushed 
 
Using  a  3/16  socket  tool  or  5mm  wrench,  attach 
the  needle  valve  to  the  port  where  you  removed 
the plug.  Be careful not to cross‐thread the small 
device when installing and do not over tighten it. 
 
 