Periodic Maintenance  
At least once per month, check the condition of the two
filters on the back of the device. If they are plugged,
simply remove them by snapping off the cover,
removing the filter media, washing it out with ordinary
soap and water, dry the filters, and re-install. If the
filters
remained
relatively
maintenance schedule accordingly.
 
 
Air Assist Cone (AAC) 
 
This accessory also requires the CCCAU. 
 
 
NEVER  install  the  AAC  without  having  the  CCCAU  installed  and 
operating,  and  NEVER  shut  off  the  needle  valve  completely.    The  lack  of  pressurized  air 
WARNING
present  in  the  cone,  during  processing,  will  allow  smoke  to  contaminate  the  lens  and  can 
destroy it within seconds. 
 
 
clean,
adjust
your
Below the device you will find a tray. With your
hands, slide the tray forwards. Inside the tray you will
find sponges that are designed to absorb the water that
was generated from condensation. In humid areas you
may need to check the sponges more than once per
week. In drier areas it is possible to extend that period.
Check them at least once per week and adjust your
schedule accordingly. The sponges may need to be
cleaned with soap and water and dried out, or replaced.