Stove Assembly

1. Glass Frame Removal

To access the firebox, use the 4 mm hex key to
remove the four socket head screws that attach the
glass frame to the firebox. See fig. 18.
• Remove the labeled lower skamol retainer from
the firebox and discard.

2. Routing the Power Supply

The power cord located in the valve compartment is
connected to the Fan Control Module which is the
main power supply for all stove operating functions.
Route the cord through the pedestal and out the rear
of the pedestal base as in fig. 18, or through the floor.
CAUTION: Take care that the pedestal base does not
pinch the power cord. You should be able to feel free
play in the cord.
The 10 foot extension power cord, supplied in
the hardware bag, is intended to connect the interior
cord to the nearest 120V house current outlet.
DO NOT CONNECT THE STOVE TO HOUSE CUR-
RENT UNTIL THE INSTALLATION IS COMPLETE AND
YOU ARE READY TO INITIATE THE FIRST BURN.
3. Connecting the Gas Supply
Gas Supply Requirements
ALL INSTALLATIONS MUST COMPLY WITH LOCAL
CODE OR IN THE ABSENCE OF LOCAL CODE, MUST
COMPLY WITH THE MOST RECENT EDITION OF THE
NATIONAL FUEL GAS CODE ANSI Z223.1/NFPA 54 OR
CAN-B149.
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED MASTER OR JOURNEYMAN PLUMBER
OR GAS-FITTER WHEN INSTALLED IN THE
COMMONWEALTH OF MASSACHUSETTS.
Shut-off Valve
All codes require a gas shut-off valve (gas
cock) and union to be installed in the supply line
within 6 feet of the appliance. This allows for
the disconnection of the stove for servicing and
maintenance. See Fig. 19.
A T-HANDLE GAS SHUT-OFF VALVE IS RE-
QUIRED IN MASSACHUSETTS IN COMPLIANCE
WITH CODE 248CMR.
14
Figure 18.
Glass frame
removal.
The stove and gas control valve must be discon-
nected from the gas supply piping during any pres-
sure testing of the system at test pressures in excess
of 1/2 psig. For pressures lower than 1/2 psig, isolate
the gas supply by closing the manual shut-off valve.
Control Valve Connection
The gas supply line connection to the stove flex
line can be made at the rear of the base plate or
through the floor. The gas supply line should be a
minimum 3/8" inside diameter, or the appropriate
size to provide sufficient gas pressure to the valve
regardless of the input setting.
The use of flexible gas appliance connectors
is acceptable in many areas in the U.S. In Canada,
methods vary depending on local code. If local codes
permit, use flexible gas line for ease of installation
and service. For those locales where flexible gas lines
are not permitted, use the 3/8" iron fitting to make
the connection at the top side of the Control Valve.
See fig. 19.
Secure all joints tightly using appropriate tools
and sealing compounds (for propane units, be sure to
use compounds that are propane resistant). Turn on
gas supply and test for gas leaks using a 50/50 soapy
water solution or a gas detector.