Installation Requirements For The Commonwealth Of Massachusetts - Jøtul GF 370 DV II Installation And Operation Instructions Manual

Direct vent gas stove
Table of Contents

Advertisement

139467_03 GF 370 DV II June 2015
THIS OWNER'S MANUAL PROVIDES INFORMATION TO
ENSURE SAFE INSTALLATION AND EFFICIENT, DEPENDABLE
OPERATION OF YOUR FIREPLACE INSERT. PLEASE READ
THESE INSTRUCTIONS IN THEIR ENTIRETY AND MAKE THEM
AVAILABLE TO ANYONE USING OR SERVICING THIS GAS
INSERT.
DO NOT ATTEMPT TO ALTER OR MODIFY THE CONSTRUCTION
OF THIS APPLIANCE OR ITS COMPONENTS. ANY
MODIFICATION OR ALTERATION WILL VOID THE WARRANTY,
CERTIFICATION AND LISTING OF THIS APPLIANCE.
THIS HEATER MUST BE INSTALLED AND MAINTAINED BY A
QUALIFIED SERVICE AGENCY.
Suggested Tools for Installation and Service
• External regulator (for Propane only)
• Piping which complies with local code
• Manual shut-off valve -
T-Handle required in Massachusetts
• Sediment trap - if required by code
• Tee joint
• Pipe wrench
• Pipe sealant
• 10 mm open end wrench
• 1/2", 7/16" open end wrench
• Phillips head screwdriver
• Flat head screwdriver
• 1/4" nut driver
2
• Work Gloves
• Safety glasses
• Torx T-20 screwdriver
• Tin snips
Installation Requirements for the
Commonwealth of Massachusetts
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED MASTER OR JOURNEYMAN PLUMBER
OR GAS-FITTER WHEN INSTALLED IN THE
COMMONWEALTH OF MASSACHUSETTS.
1. If there is not one already present, on each
floor level where there are bedroom(s), a
carbon monoxide detector and alarm shall
be placed in the living area outside the
bedroom(s). The carbon monoxide detector
shall comply with NFPA 720 (2005 Edition).
2. A carbon monoxide detector shall:
a) Be located in the room that houses the
appliance or equipment;
b) Be either hard-wired or battery powered
or both; and
c) Shall comply with NFPA 720 (2002
Edition).
3. A Product-approved vent terminal must be
used, and if applicable, a Product-approved
air intake must be used. Installation
shall be in strict compliance with the
manufacturer's instructions. A copy of
the installation instructions must remain
with the appliance or equipment at the
completion of the installation.
We recommend that
our gas products be
installed and serviced by
professionals who are
certified in the U.S. by
the National Fireplace
Institute® (NFI) as NFI Gas
Specialists.
NG / 72.41%
LP / 65.01%
Jøtul GF 370 DV II

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents