5.5
RE-ASSEMBLING THE FUEL BED
(KENILWORTH & LINEAR COAL MODELS)
NOTE : The position of the fuel-bed components are critical to the
performance of the product. Therefore please ensure that the fuel-bed
components are positioned as described in the following section prior to
requesting a service call due to soot build up, poor flame pattern etc.
5.5.1
Place the ribbed ceramic fuelbed base on top of the fuelbed support
and pull fully forwards to the burner. Make sure that the fuelbed
base is located centrally in the fire box. Ensure that the fuelbed
base fits fully down onto the fuel bed support and is not
lodged on the burner. See fig. 6 below.
Fig. 6
5.5.2
Position the two halves of the front ceramic (L/H & R/H) on the locating
channel in the front ceramic, ensuring it is located onto the lip on the
burner front ceramic support. (See fig. 7 below)
Fig. 7