Flavel FVPC**MN Installation, Maintenance & User Instructions page 18

Kenilworth & linear powerflue fuel effect gas fures
Table of Contents

Advertisement

Proceed as follows to remove the burner assembly from the firebox :-
2.5.5
Remove the burner heat shield from the front of the fire box to allow
access to the burner, as shown below in fig. 19
Fig. 19
2.5.6
Break the connection between the pressure test point elbow and the
solenoid block. Remove the four retaining screws securing the burner
to the firebox. The base of the burner unit can now be pulled
forward, allowing the burner to be removed from the fire box.
See fig. 20 below.
Fig. 20
2.5.7
Uncoil the two fire fixing cables and thread one end of each of the
cables through one of the two holes on each side of the flue outlet
shroud.
2.5.8
Position the fire carefully on the (protected) surface of the hearth and
reach into the fire opening. Thread each of the cables vertically
downwards through the pair of fixing eyes on the same side of the fire.
Thread the free end of the cables through the corresponding circular
hole on each side of the lower rear of the fire. Carefully slide the fire
box back into the fire opening and pull both cables tight.