≪ Attention of assembling ≫
Attach the Lock out of Fuser, when assembling LSD-Unit.
Inserted location of 44905601 Post-Lock-Fuser
Voltage
100V/120V
230V
45530603TH Rev.2
4
3
2
1
Lock out convex location
1
2
3
4
×
×
×
×
×
×
6.2.37 Gear-Assy-Oneway-Z33/Gear-Assy-Oneway-
Z33-R/Board-F1L(Rail unit relay PCB)
(1) Remove the LSD-Unit.(Refer to section 6.2.36)
(2) Remove the Cover-PCB-LSD ① .
(3) Disconnect all cables from the board and remove the screw(silver)(6mm) ② and
remove the Board-F1L ③ .
(4) Remove the two screws(silver)(6mm) ④ and remove the Bracket-Gear-FU ⑤ and
remove Gear-Oneway-Z33 ⑥ and Gear-Oneway-Z33-R ⑦ .