Oki C911 Maintenance Manual page 183

Hide thumbs Also See for C911:
Table of Contents

Advertisement

Oki Data CONFIDENTIAL
EDIT THICKNESS DATA Selection Items
Upper line of the display Lower line of the display
S A M P L E
P=*
PAGE
THICKNESS
T = * * * u m
: P=1
OFFSET=***
THICKNESS
T = * * * u m
: P=2
OFFSET=***
THICKNESS
T = * * * u m
: P=3
OFFSET=***
THICKNESS
T = * * * u m
: P=4
OFFSET=***
THICKNESS
T = * * * u m
: P=5
OFFSET=***
THICKNESS
T = * * * u m
: P=6
OFFSET=***
THICKNESS
T = * * * u m
: P=7
OFFSET=***
THICKNESS
T = * * * u m
: P=8
OFFSET=***
THICKNESS
T = * * * u m
: P=9
OFFSET=***
THICKNESS
T = * * * u m
: P=CHK
OFFSET=***
45530603TH Rev.2
Details
Memory
P: measurement page count
P value can be set from 1 to 9 by a cursor.
Default: 3 (Note2)
T: Setting weight of the first sheet [µ m]
OFFSET: Weight adjustment [H] T value
can be set from 46H to 10EH with a cursor.
1 µm) (Note 2)
(1LSB
T: Setting weight of the second sheet [µ m]
OFFSET: Weight adjustment [H] T value
can be set from 46H to 10EH with a cursor.
(1LSB
1 µm) (Note 1) (Note 2)
T: Setting weight of the third sheet [µ m]
OFFSET: Weight adjustment [H] T value
can be set from 46H to 10EH with a cursor.
(1LSB
1 µm) (Note 1) (Note 2)
T: Setting weight of the fourth sheet [µ m]
OFFSET: Weight adjustment [H] T value
can be set from 46H to 10EH with a cursor.
(1LSB
1 µm) (Note 1) (Note 2)
T: Setting weight of the fifth sheet [µ m]
OFFSET: Weight adjustment [H] T value
can be set from 46H to 10EH with a cursor.
1 µm) (Note 1) (Note 2)
(1LSB
T: Setting weight of the sixth sheet [µ m]
OFFSET: Weight adjustment [H] T value
can be set from 46H to 10EH with a cursor.
(1LSB
1 µm) (Note 1) (Note 2)
T: Setting weight of the seventh sheet [µ m]
OFFSET: Weight adjustment [H] T value
can be set from 46H to 10EH with a cursor.
(1LSB
1 µm) (Note 1) (Note 2)
T: Setting weight of the eighth sheet [µ m]
OFFSET: Weight adjustment [H] T value
can be set from 46H to 10EH with a cursor.
1 µm) (Note 1) (Note 2)
(1LSB
T: Setting weight of the ninth sheet [µ m]
OFFSET: Weight adjustment [H] T value
can be set from 46H to 10EH with a cursor.
(1LSB
1 µm) (Note 1) (Note 2)
T: Setting weight of the check sheet [µ m]
OFFSET: Weight adjustment [H] T value
can be set from 46H to 10EH with a cursor.
(1LSB
1 µm) (Note 2)
* Set items are effective for this test mode only. (Not written in EEPROM)
(Note 1) Up to the number of sheets set by "SAMPLE PAGE" of "EDIT THICKNESS DATA"
can be displayed and set.
SRAM
(Note 2) When the upper line of the panel shows "SAMPLE PAGE", "THICKNESS:P=*",
MENU
Pressing the
button displays the preceding test result.
SRAM
Panel display at the end of the test
Upper line of the display Lower line of the display
SRAM
OK / ERROR NAME
WEIGHT SCAN ADJ
RSLT
SRAM
Errors of media weight detection mechanical adjustment
Displayed error name
SRAM
NON-P AD ERROR:P=*
*AD value when * n th sheet does not exist is out of the specified range
Displays P=CHK when the media for checking.
THICKNESS ERR :P=*
The media weight value of *n th sheet is out of the specified range
SRAM
Displays P=CHK when the media for checking .
SLANT ERROR :P=*
The slant of *n th sheet is out of the specified range.
SNS AD ERROR :P=*
The difference of output at the presence or absence of *n th sheet is
out of the specified range.
SRAM
SNSOR ERROR
Failure in sensor
WEIGHT SCAN ADJ RESULT
SRAM
Upper line of the display Lower line of the display
PAPER
SET=***um
THICKNESS:P=1
OUT=***um
SRAM
PAPER
SET=***um
THICKNESS:P=2
OUT=***um
SRAM
PAPER
SET=***um
THICKNESS:P=3
OUT=***um
SRAM
5. MAINTENANCE MENUS
button displays the next test result. Pressing the
Details
Displays only "OK" in the upper line of the display
when no error occurs.
Displays an error name when an error occurs.
Displays "**** RESULT" corresponding to the test
executed in the lower line of the display
Contents
Details
In the first sheet
SET: Setting weight [µ m]
OUT: Weight [µ m]when detected by the
standard sensitivity (1.4µ m)
In the second sheet
SET: Setting weight [µ m]
OUT: Weight [µ m]when detected by the
standard sensitivity (1.4µ m) (Note 1)
In the third sheet
SET: Setting weight [µ m]
OUT: Weight [µ m]when detected by the
standard sensitivity (1.4µ m) (Note 1)
MENU
Memory
SRAM
SRAM
SRAM
5-42