Oki Data CONFIDENTIAL
6.2.23 Board-AHR(High-voltage relay PCB)
(1) Remove the Motor-Assy-ID.(Refer to section 6.2.22)
(2) Remove the ten screws(silver)(6mm) ① and remove the Board-AHR ② .
45530603TH Rev.2
①
×10
②
×5
6.2.24 Board-TAGRW/FFC-Cable/Motor-FAN
(1) Remove the Plate-Box-MainPCB.(Refer to section 6.2.21)
(2) Remove the Guide-Cable-FFC.(Refer to section 6.2.22)
(3) Remove the screw(silver)(6mm) ① and remove the TAGRW-Assy ② , ③ .
(4) Remove the two screws(silver)(6mm) ④ and remove the Board-RFID ③ from the
Plate-Shield-TAGRW ② .
(5) Remove the Motor-FAN-Assy ⑤ and remove the Motor-FAN ⑥ .
(6) Remove the four screws(silver)(6mm) ⑦ and remove the Plate-Assy-Pillar-B ⑧ .
(7) Remove the Motor-FAN ⑨ .
6. REPLACEMENT OF PARTS
④
×2
①
③
②
⑨
⑤
⑥
⑧
⑦
×4