Oki Data CONFIDENTIAL
2.3.36 High-voltage Power Unit
(1) Remove the Contact Assy. (See Sec. 2.3.34.)
(2) Remove the connector of the High-voltage Power Unit 1.
(3) Unscrew 2 screws 2 and remove the High-voltage Power Unit 1 and HV Tape Harness 3.
2
3
2
1
Figure 2-3-36 High-voltage Power Unit
59 /