7 - INSTALLATION AND ASSEMBLY OF TANK

Connection of pressure gauge.

a) Remove fitting "R" from the tip of the capillary "C".
b) Unscrew fitting "T" on the hydraulic unit.
c) Insert fitting "T" on the capillary by means of the slot.
d) Screw fitting "T" onto the hydraulic unit.
Manual tank
CONNECTION OF PRESSURE GAUGE TO HYDRAULIC KIT (manual tank)
Refill tank
56
C = PRESSURE GAUGE CAPILLARY
R = FITTING ON CAPILLARY
T = FITTING MOUNTED ON HYDRAULIC UNIT
R
T
C
CONNECTION OF PRESSURE GAUGE TO HYDRAULIC
KIT (refill tank)