Advertisement

5-PLUMBING CONNECTION

PLUMBING CONNECTION
IMPORTANT:
The connections depend on the type of hydraulic kit installed and on the type of System Configuration.
IMPORTANT!
If installation of the product involves interaction with another, pre-existing system complete with heating
equipment (gas boiler, methane boiler, diesel boiler, etc.), contact qualified personnel, who subsequently will be
responsible for conformity of the system in compliance with the applicable law in force.
The Company declines all responsibility for damage to persons or things in the event of failed or incorrect operation,
if the aforementioned warnings are not complied with.
IMPORTANT!!!
FLUSH THE ENTIRE SYSTEM BEFORE CONNECTING THE BOILER IN ORDER TO REMOVE RESIDUES AND DEPOSITS.
Always install gate valves upstream from the boiler so as to disconnect it from the plumbing system should it be
necessary to move it, or when it requires routine and/or special maintenance.
Connect the boiler using hoses so that the boiler is not too strictly connected to the system, and to allow slight
movements.
HYDRAULIC KIT
The boilers must be connected to an optional hydraulic kit with or without domestic water production.
SYSTEM WASHING
To protect the heating system from harmful corrosion, fouling or deposits, it is of the utmost importance, before installing the product, to
wash the system in compliance with UNI-CTI 8065, using appropriate products such as, for example, Sentinel X300 (new systems), X400
and X800 (old systems) or Fernox Cleaner F3.
Complete instructions are provided with the products but, for further clarifications, please directly contact the manufacturer SENTINEL
PERFORMANCE SOLUTIONS LTD or Fernox COOKSON ELECTRONICS. After flushing the system, to protect it against corrosion and deposits,
we recommend the use of inhibitors such as Sentinel X100 or Fernox Protector F1.
It is important to check the concentration of the inhibitor after each change to the system and during maintenance as prescribed by
manufacturers (specific tests are available at dealers).
The discharge of the safety valve must be connected to a collecting funnel for conveying the possible dredges in case of intervention.
Attention: Failure to clean the heating system and to add a suitable inhibitor will void the warranty of the equipment
and other accessories such as for example pumps and valves.