Auto-Eco; Eco Stop; Pump On T - RED LOGIKA 25-35 Installation Manual

Table of Contents

Advertisement

2 - MENU OPTIONS
d - Auto-Eco
The Auto-Eco function turns the boiler off automatically at the configured time of the "Eco Stop T" parameter when no heat is required by
the devices connected to the boiler: external thermostat (configurations 1-2-3), flow switch (configuration 2), thermostat/puffer probe
(configuration 5-6) or thermostat/boiler probe (configuration 3-4). If all the devices present are satisfied, the "ECO stop T" timer starts to
count down.
When the boiler turns off, ECO - ECO ACTIVE appears on the panel.
The following conditions have to be met simultaneously for the ECO to restart:
Power recall
5 minutes have passed since shut-down.
TH
O < TSetH
O.
2
2
NOTE: In certain system configurations, it can be useful to disable automatic shut-down of the boiler (e.g. in configurations 2 or 3) and
keep the system running at minimum power. In other configurations, this function cannot be disabled.
Disable the Auto-Eco function as follows:
Press key 3 ''menu'' .
Use the 1-2 arrow keys to scroll through and select ''Settings''
Press 3 "menu" to confirm.
Use the 1-2 arrow keys to scroll through and select ''Auto-Eco'' .
Press 3 "menu" to confirm.
Use keys 4 (+) and 5 (-) to select ''Off'' .
Press 3 ''menu'' to confirm and 6 ''esc'' to exit.
e - Eco stop T (Eco stop time)
The "ECO stop T" can be adjusted to ensure correct operation of the system in which the boiler is installed and to avoid constant stopping
and starting when heat requirements are subject to change suddenly.
Select the Eco stop T function as follows:
Press key 3 ''menu'' .
Use the 1-2 arrow keys to scroll through and select ''Settings''
Press 3 "menu" to confirm.
Use the 1-2 arrow keys to scroll through and select ''Eco stop T'' .
Press 3 "menu" to confirm.
Use keys 4 (+) and 5 (-) to enter the minutes.
Press 3 ''menu'' to confirm and 6 ''esc'' to exit.
f - Pump On T (pump temperature) (ONLY FOR EXPERIENCED USERS)
This option enables adjustment of the pump activation temperature.
Select the Pump On T function as follows:
Press key 3 ''menu'' .
Use the 1-2 arrow keys to scroll through and select ''Settings''
Press 3 "menu" to confirm.
Use the 1-2 arrow keys to scroll through and select ''Pump On T'' .
Press 3 "menu" to confirm.
Use keys 4 (+) and 5 (-) to enter the °C.
Press 3 ''menu'' to confirm and 6 ''esc'' to exit.
Technical Dept. - All rights reserved - Reproduction is prohibited
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents